Signal processing method based on connection fitting of echo peak point with a large slope for ultrasonic gas flow meter.

作者信息

Ma Jie, Xu Ke-Jun, Jiang Zhen, Zhang Lun, Xu Hao-Ran

机构信息

School of Electrical and Automation Engineering, Hefei University of Technology, Hefei 230009, People's Republic of China.

出版信息

Rev Sci Instrum. 2021 Jan 1;92(1):015105. doi: 10.1063/5.0021801.

DOI:10.1063/5.0021801
PMID:33514197
Abstract

Ultrasonic gas flow meters are especially suitable for measurement in pipelines with large diameters. However, on the one hand, it is difficult to find a stable feature point to calculate the duration of propagation of the ultrasonic signal, through which we can obtain the real-time flow rate of the gas, and on the other hand, the computation incurred by signal processing methods to this end is burdensome and affects the real-time performance of the flow meter. To solve these problems, this study examines the characteristics of the stability of the echo signal and patterns of variation in the echo contour at different flow rates of gas. We found that peak points of the middle part of the rising segment of the echo signal were relatively stable, and the slope of the envelope of this part was always relatively large but constant, which indicates that peak points in this part were approximately distributed along a straight line. This finding is used to develop a signal processing method based on the connection fitting of the echo peak point with a large slope. This method is easy to implement, incurs a small amount of calculation, and has strong anti-interference ability. Moreover, it can guide research on signal processing methods and the stability of the echo signal. The proposed method was implemented on a dual-core hardware system, and the results of calibration show that it can attain 1.0-level accuracy over a measurable range of 30 m/h-1100 m/h.

摘要

相似文献

1
Signal processing method based on connection fitting of echo peak point with a large slope for ultrasonic gas flow meter.
Rev Sci Instrum. 2021 Jan 1;92(1):015105. doi: 10.1063/5.0021801.
2
Echo signal envelope fitting based signal processing methods for ultrasonic gas flow-meter.基于回波信号包络拟合的超声波气体流量计信号处理方法
ISA Trans. 2019 Jun;89:233-244. doi: 10.1016/j.isatra.2018.12.035. Epub 2018 Dec 27.
3
Energy transfer model and its applications of ultrasonic gas flow-meter under static and dynamic flow rates.静态和动态流量下超声气体流量计的能量传递模型及其应用
Rev Sci Instrum. 2016 Jan;87(1):015107. doi: 10.1063/1.4939670.
4
Time Delay Study of Ultrasonic Gas Flowmeters Based on VMD-Hilbert Spectrum and Cross-Correlation.基于变分模态分解-希尔伯特谱和互相关的超声气体流量计时间延迟研究
Sensors (Basel). 2024 Feb 23;24(5):1462. doi: 10.3390/s24051462.
5
Multipath ultrasonic gas flow-meter based on multiple reference waves.基于多参考波的多路径超声气体流量计。
Ultrasonics. 2018 Jan;82:145-152. doi: 10.1016/j.ultras.2017.07.010. Epub 2017 Jul 18.
6
[Ultrasonic imaging research at points in neck-type cervical spondylosis].[颈型颈椎病相关部位的超声成像研究]
Zhongguo Zhen Jiu. 2017 Apr 12;37(4):395-399. doi: 10.13703/j.0255-2930.2017.04.012.
7
Separated two-phase flow regime parameter measurement by a high speed ultrasonic pulse-echo system.采用高速超声脉冲回波系统测量分离两相流流型参数。
Rev Sci Instrum. 2007 Nov;78(11):114901. doi: 10.1063/1.2804117.
8
Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines.实验确定刀闸阀后流动干扰对夹式超声流量计在管道上的指示的影响。
Sensors (Basel). 2023 May 11;23(10):4677. doi: 10.3390/s23104677.
9
Physics Constrained High-Precision Data-Driven Modeling for Multi-Path Ultrasonic Flow Meter in Natural Gas Measurement.用于天然气测量中多路径超声流量计的物理约束高精度数据驱动建模
Sensors (Basel). 2024 Jul 12;24(14):4521. doi: 10.3390/s24144521.
10
A Novel Ultrasonic Method for Liquid Level Measurement Based on the Balance of Echo Energy.一种基于回波能量平衡的新型液位超声测量方法。
Sensors (Basel). 2017 Mar 28;17(4):706. doi: 10.3390/s17040706.