Schorn Lara, Sproll Christoph, Depprich Rita, Kübler Norbert R, Rana Majeed, Singh Daman D, Lommen Julian
Department of Oral, Maxillofacial and Facial Plastic Surgery, University Hospital Düsseldorf, Düsseldorf, Germany.
Case Rep Dent. 2021 Jan 16;2021:8820381. doi: 10.1155/2021/8820381. eCollection 2021.
Dislocation of a fractured hypodermic needle is a complication requiring immediate and adequate emergency treatment. In this case report, 3D navigation is evaluated for its use to recover a quickly moving fractured needle. The needle was recovered safely, but it could be demonstrated that navigational planning has to be conducted right before surgery and other navigational tools, such as ultrasound, should be considered as well. Furthermore, an approach is suggested for treatment during pandemic crises such as COVID-19.
皮下注射针头骨折脱位是一种需要立即进行充分急救治疗的并发症。在本病例报告中,对三维导航用于找回快速移动的骨折针头的情况进行了评估。针头被安全找回,但可以证明,导航规划必须在手术前立即进行,并且还应考虑使用其他导航工具,如超声。此外,还提出了一种在COVID-19等大流行危机期间的治疗方法。