用于锁定钢板远端螺钉的单皮质固定不会损害开放性楔形高位胫骨截骨术的力学性能。

Monocortical fixation for locking plate distal screws does not impair mechanical properties in open-wedge high tibial osteotomy.

作者信息

Itou Junya, Kuwashima Umito, Itoh Masafumi, Kuroda Koichi, Yokoyama Yasuharu, Okazaki Ken

机构信息

Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan.

Olympus Terumo Biomaterials Corp., Sasazuka NA Bldg., 1-50-1 Sasazuka, Shibuya-ku, Tokyo, 151-0073, Japan.

出版信息

BMC Musculoskelet Disord. 2021 Feb 8;22(1):157. doi: 10.1186/s12891-021-03999-y.

Abstract

BACKGROUND

The neurovascular bundle containing the deep peroneal nerve has a potential risk of injury during open-wedge high tibial osteotomy (OWHTO), particularly due to drilling for bicortical fixation at distal screw holes. Therefore, monocortical fixation is recommended for distal fixation of a long locking plate as long as good stability is ensured. The purpose of this study was to analyse the biomechanical properties of monocortical fixation of distal locking screws for OWHTO.

METHODS

Three-dimensional models of bone and fixation materials simulating OWHTO were created using computed tomographic data of patients and material data of a T-shaped long locking plate and screws. Three of the four distal screws of the locking plate were chosen for a bicortical fixation or monocortical fixation procedure. In addition, loss of correction was assessed by measuring the medial proximal tibial angle (MPTA) in patients who underwent OWHTO with two bicortical and two monocortical distal fixation screws at 1 month and 1 year after surgery.

RESULTS

No significant differences in stress were observed in either the normal or osteoporotic bone model between the monocortical and bicortical fixation models, including in the area of the lateral hinge at the osteotomy site. Furthermore, there were no significant differences in MPTA between the early post-operative period and 1-year follow-up.

CONCLUSIONS

The monocortical fixation method for three distal screws of the locking plate did not worsen the mechanical properties of fixation for OWHTO using a long locking plate with four proximal and four distal screws. In actual surgery, the number of distal bicortical screws should be reduced based on the patient's condition, taking into account the risk of lateral hinge fracture and unexpected surgical complications. Using at least two bicortical screws would be practical considering the various factors related to reduced fixing ability.

摘要

背景

在开放性楔形高位胫骨截骨术(OWHTO)期间,包含腓深神经的神经血管束存在损伤风险,特别是在远端螺钉孔进行双皮质固定钻孔时。因此,只要能确保良好的稳定性,建议对长锁定钢板的远端固定采用单皮质固定。本研究的目的是分析OWHTO中远端锁定螺钉单皮质固定的生物力学特性。

方法

利用患者的计算机断层扫描数据以及T形长锁定钢板和螺钉的材料数据,创建模拟OWHTO的骨和固定材料三维模型。锁定钢板的四个远端螺钉中的三个用于双皮质固定或单皮质固定操作。此外,在术后1个月和1年对接受OWHTO且远端采用两个双皮质和两个单皮质固定螺钉的患者,通过测量胫骨近端内侧角(MPTA)来评估矫正丢失情况。

结果

在正常或骨质疏松骨模型中,单皮质和双皮质固定模型之间在应力方面未观察到显著差异,包括截骨部位外侧铰链区域。此外,术后早期和1年随访之间MPTA也无显著差异。

结论

对于使用带有四个近端和四个远端螺钉的长锁定钢板的OWHTO,锁定钢板三个远端螺钉的单皮质固定方法不会恶化固定的力学性能。在实际手术中,应根据患者情况减少远端双皮质螺钉数量,同时考虑外侧铰链骨折风险和意外手术并发症。考虑到与固定能力降低相关的各种因素,使用至少两个双皮质螺钉是可行的。