Department of Plastic and Reconstructive Surgery, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Department of Hand Surgery, Ningbo Sixth Hospital, Ningbo.
Ann Plast Surg. 2021 Oct 1;87(4):451-456. doi: 10.1097/SAP.0000000000002741.
Dynamic infrared thermography provides a new imaging method of perforator detection. This study introduces an augmented technique to improve its accuracy by tourniquet-reperfusion and reports its preliminary use in the distal lower leg reconstruction.
A tourniquet (450 mm Hg) was applied for 3 minutes on proximal thighs. After the tourniquet release, the rewarming rate and pattern of hotspots were observed by thermography to delineate the location and quality of perforators. The results were compared with those detected by computed tomographic angiography. Clinically, the local transferred posterior tibial artery or peroneal artery propeller perforator flap was performed in 9 patients for the distal lower leg reconstruction.
There was a 20- to 140-second "perforator observing window" after the tourniquet release. Tourniquet-reperfusion augmented thermal imaging method (TRATIM) had a sensitivity of 90.3% and a positive predictive value of 93.3%. The TRATIM and computed tomographic angiography had an excellent concordance with a kappa index value of 0.839 (P < 0.001). Based on the TRATIM, 9 propeller perforator flaps were successfully designed and raised for the distal lower leg resurfacing. All flaps survived entirely, except one with size of 1.0 cm × 2.0 cm that had terminal necrosis.
The TRATIM is a quick, easy, cheap, and reliable approach for perforator detection in the lower leg. With the aid of TRATIM, a customized propeller perforator flap could be raised efficiently for the distal lower leg reconstruction.
动态红外热成像提供了一种新的穿支探测成像方法。本研究介绍了一种增强技术,通过止血带再灌注来提高其准确性,并报告了其在小腿远端重建中的初步应用。
在大腿近端施加 450mmHg 的止血带 3 分钟。止血带松开后,通过热成像观察热点的复温率和模式,以描绘穿支的位置和质量。结果与计算机断层血管造影术的检测结果进行比较。临床上,9 例患者行局部游离腓动脉或比目鱼肌动脉桨状穿支皮瓣用于小腿远端重建。
止血带松开后有 20-140 秒的“穿支观察窗口”。止血带再灌注增强热成像法(TRATIM)的灵敏度为 90.3%,阳性预测值为 93.3%。TRATIM 和计算机断层血管造影术具有极好的一致性,kappa 指数值为 0.839(P<0.001)。根据 TRATIM,成功设计并掀起 9 个桨状穿支皮瓣用于小腿远端覆盖。除 1 个 1.0cm×2.0cm 大小的皮瓣末端坏死外,所有皮瓣均完全存活。
TRATIM 是一种快速、简便、经济、可靠的小腿穿支探测方法。在 TRATIM 的辅助下,可以有效地掀起定制的桨状穿支皮瓣,用于小腿远端重建。