Suppr超能文献

稳定型冠状动脉病变和急性冠状动脉综合征患者的可比较新生内膜愈合:3 个月光学相干断层成像分析。

Comparable neointimal healing in patients with stable coronary lesions and acute coronary syndrome: 3-month optical coherence tomography analysis.

机构信息

Department of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, Osaka, 543-0035, Japan.

Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan.

出版信息

Int J Cardiovasc Imaging. 2021 Jul;37(7):2095-2105. doi: 10.1007/s10554-021-02189-0. Epub 2021 Feb 16.

Abstract

We aimed to assess a possible difference of the neointimal coverage status and its quality after implantation of the current-generation metallic stents in patients with acute coronary syndrome (ACS) vs. stable coronary lesions (non-ACS). We comprehensively analyzed three prospective single-center observational studies RESTORE (UMIN000033009), HEAL-BioFreedom (UMIN000029692), and HEAL-BioFreedom ACS (UMIN000034769). All patients who received successful optical coherence tomography (OCT) examination at planned 3-month follow-up after stent implantation were analyzed. Study population was divided into two groups, ACS vs. non-ACS groups. We evaluated standard OCT variables, coverage percent, and the quantitative light property values including light intensity, attenuation, and backscatter of neointima. A total of 177 lesions from 154 patients (ACS 44 lesions vs. non-ACS 133 lesions) were analyzed. At 3-month follow-up, coverage percent (ACS 91.5  ±  9.5% vs. non-ACS 91.8  ±  9.0%, P = 0.722) and neointimal thickness (ACS 59.5  ±  32.3 µm vs. non-ACS 58.2  ±  32.3 µm, P = 0.760) did not significantly differ. Light property values were similar between both groups (light intensity 159.29  ±  72.20 vs. 159.45   ± 63.78, P = 0.654; light attenuation 0.88  ±  0.26 vs. 0.87   ±  0.24 m, P = 0.988; backscatter 4.86   ±  0.58 vs. 4.83   ±  0.57, P = 0.812). The similarity of the neointimal quality in ACS and non-ACS patients was consistent across the 6 different types of current-generation metallic stents (P for interaction  > 0.05). Our findings suggested the comparable neointimal characteristics 3 months after implantation of the current-generation metallic stents in patients with ACS and stable coronary lesions by quantitative OCT methodology.

摘要

我们旨在评估当前一代金属支架植入后急性冠状动脉综合征(ACS)与稳定型冠状动脉病变(非 ACS)患者的新生内膜覆盖状态及其质量的可能差异。我们综合分析了三项前瞻性单中心观察性研究 RESTORE(UMIN000033009)、HEAL-BioFreedom(UMIN000029692)和 HEAL-BioFreedom ACS(UMIN000034769)。所有接受支架植入后 3 个月计划随访时成功行光学相干断层扫描(OCT)检查的患者均纳入分析。研究人群分为 ACS 组和非 ACS 组。我们评估了标准 OCT 变量、覆盖率和包括光强度、衰减和新生内膜反向散射在内的定量光特性值。共分析了 154 名患者的 177 个病变(ACS 组 44 个病变,非 ACS 组 133 个病变)。在 3 个月随访时,ACS 组的覆盖率(91.5±9.5%)与非 ACS 组(91.8±9.0%)无显著差异(P=0.722),新生内膜厚度(ACS 组 59.5±32.3 µm vs. 非 ACS 组 58.2±32.3 µm,P=0.760)也无显著差异。两组间光特性值相似(光强度 159.29±72.20 vs. 159.45±63.78,P=0.654;光衰减 0.88±0.26 vs. 0.87±0.24 m,P=0.988;反向散射 4.86±0.58 vs. 4.83±0.57,P=0.812)。通过定量 OCT 方法,ACS 患者和稳定型冠状动脉病变患者植入当前一代金属支架 3 个月后新生内膜质量的相似性在 6 种不同类型的当前一代金属支架中一致(P 交互>0.05)。我们的研究结果表明,在急性冠状动脉综合征和稳定型冠状动脉病变患者中,当前一代金属支架植入后 3 个月的新生内膜特征具有可比性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验