Wu Yao, Chen Buguo, Dong Ziqiang, Yan Chengshi, Zheng Dawei, Zhu Hui
Department of Hand Microsurgery, Xuzhou Renci Hospital, Xuzhou Jiangsu, 221004, P.R.China.
.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2021 Feb 15;35(2):206-209. doi: 10.7507/1002-1892.202009022.
To investigate the effectiveness of the modified great toe fibular flap using the distal artery pedicle as reflux vein for repairing distal phalanx finger wound.
Between June 2018 and January 2020, 15 patients who suffered tissue defect of the distal phalanx finger were treated, including 12 males and 3 females, the average age was 40.2 years (range, 24-56 years). All of them were caused by machine crush injury. There were 2 cases of thumb, 6 cases of index finger, 3 cases of middle finger, 3 cases of ring finger, and 1 case of little finger. The defects ranged from 1.7 cm×1.3 cm to 3.0 cm×2.0 cm. The time from injury to admission was 0.6-4 hours, with an average of 2.3 hours. The medial fibular proper digital artery was further dissociated to the distal end and anastomosed with the recipient vein as the reflux vein. The area of flaps ranged from 2.0 cm×1.5 cm to 3.2 cm×2.2 cm.
All the flaps survived without vascular crisis, and the wounds healed by first intention. Except for 1 case that the suture was too tight, the incision was partially split after the stitches were removed, and it healed spontaneously after dressing change, the other patients had good healing of the donor site incision and normal foot function. All 15 patients were followed up 3-18 months, with an average of 9.3 months. The appearance of finger pulps were satisfactory with full and threaded. The color, texture, and elasticity of the flaps were good, and the two-point discrimination was 6-8 mm at last follow-up. The flexion and extension of fingers were normal. At last follow-up, hand function was evaluated according to the upper limb function evaluation trial standard of the Chinese Medical Association Hand Surgery Society, and the results were 13 cases of excellent and 2 cases of good.
Modified great toe fibular flap using the distal arterial pedicle as a reflux vein can improve the venous drainage of the flap and contribute to increase the success rate of the flap without additional injury.
探讨以远端动脉蒂作为回流静脉的改良踇趾腓侧皮瓣修复手指末节创面的有效性。
2018年6月至2020年1月,收治15例手指末节组织缺损患者,其中男12例,女3例,平均年龄40.2岁(24~56岁)。均为机器碾压伤所致。拇指2例,示指6例,中指3例,环指3例,小指1例。缺损范围为1.7 cm×1.3 cm至3.0 cm×2.0 cm。受伤至入院时间为0.6~4小时,平均2.3小时。将腓侧趾固有动脉向远端进一步游离,与受区静脉吻合作为回流静脉。皮瓣面积为2.0 cm×1.5 cm至3.2 cm×2.2 cm。
所有皮瓣均成活,未发生血管危象,创面一期愈合。除1例因缝合过紧,拆线后切口部分裂开,换药后自行愈合外,其余患者供区切口愈合良好,足部功能正常。15例患者均获随访,时间3~18个月,平均9.3个月。指腹外观满意,饱满、有螺纹。皮瓣颜色、质地、弹性良好,末次随访时两点辨别觉为6~8 mm。手指屈伸功能正常。末次随访时,按照中华医学会手外科学会上肢功能评定试用标准对手功能进行评定,结果为优13例,良2例。
以远端动脉蒂作为回流静脉的改良踇趾腓侧皮瓣可改善皮瓣的静脉回流情况,有助于提高皮瓣成活率,且无需额外损伤。