Abstract

BACKGROUND

Fluoroscopic imaging involves exposure of the patients and the laboratory staff to ionizing radiation. One of the strategies that reduce such exposure in an electrophysiology laboratory is using a three-dimensional electroanatomic mapping (3D EAM) system for performing these procedures. In this analysis, we have analyzed the effect of fluoroscopy frame rate on the radiation exposure and in-hospital outcomes in ablation procedures performed under 3D EAM guidance.

METHODS

We retrospectively analyzed all the ablation procedures performed under 3D EAM guidance at our institute from September 2015 to December 2018. The procedures were divided into two groups based on whether the procedures were performed before (pre) or after (post) January 26, 2018. After January 2018, fluoroscopy was used at a frame rate of 3.75 frames per second (fps). Radiation exposure indices and in-hospital outcomes were compared between the two groups.

RESULTS

Ablation procedures included in the analysis were ventricular arrhythmias (n = 192), atrial flutter (115), atrial tachycardia (AT) (43), and atrial fibrillation (AF) (30). Over the study period, there was a significant reduction in procedure time, fluoroscopy time, dose area product, and effective dose (ED) ( < .001). Except for AT and AF ablation procedures, there was a significant reduction in the radiation exposure indices when the "post" group was compared with the "pre" group ( ≤ .02). The decrease in the frame rate had no significant effect on in-hospital outcomes.

CONCLUSION

The use of 3D EAM combined with decreasing the fluoroscopy frame rate significantly reduced the total radiation exposure without adversely affecting in-hospital outcomes.

摘要

背景

荧光透视成像会使患者和实验室工作人员暴露于电离辐射中。在电生理实验室减少此类暴露的策略之一是使用三维电解剖标测(3D EAM)系统来执行这些操作。在本分析中,我们分析了荧光透视帧率对在3D EAM引导下进行的消融手术中辐射暴露及院内结局的影响。

方法

我们回顾性分析了2015年9月至2018年12月在我院3D EAM引导下进行的所有消融手术。根据手术是在2018年1月26日之前(术前)还是之后(术后)进行,将这些手术分为两组。2018年1月之后,荧光透视以每秒3.75帧(fps)的帧率使用。比较两组之间的辐射暴露指标和院内结局。

结果

纳入分析的消融手术包括室性心律失常(n = 192)、心房扑动(115)、房性心动过速(AT)(43)和心房颤动(AF)(30)。在研究期间,手术时间、荧光透视时间、剂量面积乘积和有效剂量(ED)均显著减少(P <.001)。除AT和AF消融手术外,“术后”组与“术前”组相比,辐射暴露指标显著降低(P≤.02)。帧率的降低对院内结局无显著影响。

结论

使用3D EAM并降低荧光透视帧率可显著降低总辐射暴露,且不会对院内结局产生不利影响。

相似文献

3
Advanced electrophysiologic mapping systems: an evidence-based analysis.
Ont Health Technol Assess Ser. 2006;6(8):1-101. Epub 2006 Mar 1.
6
Radiation exposure in cryoballoon ablation compared to radiofrequency ablation with three-dimensional electroanatomic mapping in atrial fibrillation patients.
Herzschrittmacherther Elektrophysiol. 2021 Mar;32(1):99-107. doi: 10.1007/s00399-020-00738-z. Epub 2021 Jan 14.
7
Reduction of fluoroscopy dose for cardiac electrophysiology procedures: A feasibility and safety study.
Eur J Radiol. 2019 Jan;110:105-111. doi: 10.1016/j.ejrad.2018.11.019. Epub 2018 Nov 20.
8
Catheter Ablation of Atrial Fibrillation Without Radiation Exposure Using A 3D Mapping System.
J Atr Fibrillation. 2015 Feb 28;7(5):1167. doi: 10.4022/jafib.1167. eCollection 2015 Feb-Mar.
9
Feasibility of zero or near zero fluoroscopy during catheter ablation procedures.
Cardiol J. 2019;26(3):226-232. doi: 10.5603/CJ.a2018.0029. Epub 2018 Apr 3.

引用本文的文献

1
Energy barriers govern catheter herniation during endovascular procedures: a 2.5D vascular flow model analysis.
J R Soc Interface. 2024 Oct;21(219):20240333. doi: 10.1098/rsif.2024.0333. Epub 2024 Oct 23.

本文引用的文献

2
Minimizing Radiation in the Modern Electrophysiology Laboratory.
J Innov Card Rhythm Manag. 2018 Aug 15;9(8):3265-3270. doi: 10.19102/icrm.2018.090805. eCollection 2018 Aug.
3
Cardiac Mapping Systems: Rhythmia, Topera, EnSite Precision, and CARTO.
Card Electrophysiol Clin. 2019 Sep;11(3):449-458. doi: 10.1016/j.ccep.2019.05.006.
4
Fundamentals of Cardiac Mapping.
Card Electrophysiol Clin. 2019 Sep;11(3):433-448. doi: 10.1016/j.ccep.2019.05.005.
5
Reducing radiation exposure during atrial fibrillation ablation using lectures to promote awareness.
Open Heart. 2019 Jun 24;6(1):e000982. doi: 10.1136/openhrt-2018-000982. eCollection 2019.
7
Decreased operator X-ray exposure by optimized fluoroscopy during radiofrequency ablation of common atrial flutter.
Diagn Interv Imaging. 2018 Oct;99(10):625-632. doi: 10.1016/j.diii.2018.04.008. Epub 2018 May 10.
9
Fluoroless Catheter Ablation of Cardiac Arrhythmias: A 5-Year Experience.
Pacing Clin Electrophysiol. 2017 Apr;40(4):425-433. doi: 10.1111/pace.13038. Epub 2017 Mar 3.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验