Suppr超能文献

流口水的鼻唇沟计数是一种准确的定量测量方法吗?

Is bib count an accurate quantitative measure of drooling?

机构信息

Faculty of Medicine, McGill University, Montreal, Canada.

Department of Otolaryngology - Head and Neck Surgery, Montreal Children's Hospital, Montreal, Canada.

出版信息

Int J Pediatr Otorhinolaryngol. 2021 Apr;143:110657. doi: 10.1016/j.ijporl.2021.110657. Epub 2021 Mar 1.

Abstract

BACKGROUND

Bib count is a frequently used measure amongst pediatric otolaryngologists to quantify drooling status. The plethora of bibs used, including important differences in material, size, and shape, makes one question the validity of bib count as an accurate surrogate measure of drooling frequency or severity. To date, no study has addressed this question in the literature. We evaluated the correlation between drooling frequency, drooling severity, and number of bibs changed to better guide clinical practice in saliva management in a large pediatric patient population.

METHODS

This was a retrospective cohort study comprising 414 pediatric patients from 2014 to 2019. Patients were included if there was presence of drooling and completed the Daniel Drooling Impact Score Questionnaire. The primary outcome was the severity of drooling, frequency of drooling, and number of bibs changed. Age, sex, feeding type and diagnosis were also data points collected. Pearson's coefficient of correlation and multiple regression analysis were used to analyze association between variables.

RESULTS

Bib count, frequency of drooling, and severity of drooling were all positively correlated. The strongest positive correlation was between drooling frequency and drooling severity (r = 0.659; p < 0.01), followed by bib count and drooling severity (r = 0.541; p < 0.01), then bib count and drooling frequency (r = 0.416; p < 0.01). In multivariate regression analysis, only bib count was a statistically significant positive predictor of drooling severity (β=1.14, p < 0.01). Feeding type and underlying diagnosis also influenced bib count.

CONCLUSIONS

The number of bibs changed per day is an accurate predictor of sialorrhea that correlates positively with drooling severity and frequency despite the variability and lack of standardization in bibs. Consistent definitions of what constitutes a bib and its characteristics should be collected during drooling evaluation.

摘要

背景

涎液计数是儿科耳鼻喉科医生常用的一种量化流涎状态的方法。目前使用的涎液收集器种类繁多,包括在材料、尺寸和形状方面存在重要差异,这使得人们质疑涎液计数作为流涎频率或严重程度的准确替代测量指标的有效性。迄今为止,文献中尚无研究探讨这一问题。我们评估了流涎频率、流涎严重程度和更换的涎液收集器数量之间的相关性,以便更好地指导在大量儿科患者群体中进行唾液管理的临床实践。

方法

这是一项回顾性队列研究,纳入了 2014 年至 2019 年期间的 414 名儿科患者。纳入标准为存在流涎并完成了 Daniel 流涎影响评分问卷的患者。主要结局是流涎严重程度、流涎频率和更换的涎液收集器数量。还收集了年龄、性别、喂养类型和诊断等数据点。采用 Pearson 相关系数和多元回归分析来分析变量之间的关联。

结果

涎液收集器数量、流涎频率和流涎严重程度均呈正相关。流涎频率和流涎严重程度之间存在最强的正相关(r=0.659;p<0.01),其次是涎液收集器数量和流涎严重程度(r=0.541;p<0.01),然后是涎液收集器数量和流涎频率(r=0.416;p<0.01)。在多元回归分析中,只有涎液收集器数量是流涎严重程度的统计学上显著的正预测因子(β=1.14,p<0.01)。喂养类型和潜在诊断也影响了涎液收集器数量。

结论

每天更换的涎液收集器数量是流涎的准确预测指标,与流涎严重程度和频率呈正相关,尽管涎液收集器存在差异且缺乏标准化。在流涎评估过程中,应收集关于涎液收集器的定义及其特征的一致信息。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验