Kandaswamy Chandrasekar, Anandaram Sreekanth, Presley S I Davis, Shabeer Ahammed T P
Agilent Technologies, Bangalore, India.
National Institute of Technology, Trichy, 620 015 India.
J Food Sci Technol. 2021 Mar;58(3):911-920. doi: 10.1007/s13197-020-04605-0. Epub 2020 Jun 27.
A gas chromatography tandem mass spectrometry method was developed for simultaneous determination of 133 pesticides in Black pepper (). QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) sample preparation method is preferred over multistep methods. Extraction was done by using acetonitrile followed by clean up using graphitized carbon, primary secondary amine and octadecyl silica (C). Even after the cleanup, non-volatile co-extractives stick to the liner and column which results in affecting the performance of the instrument and volatile co-extractives impact the analysis by enhancing the analyte concentration. So we evaluated a dilution procedure to overcome the drawbacks. The limit of quantification of 0.01 mg kg was achieved for fifty times diluted sample extract with S/N ≥ 10. The recovery was between 70 and 120% for 0.01, 0.025 and 0.05 mg kg for fortified samples and corresponding precision was between 3 and 16% RSD. The seven-level calibration curve shows a regression co-efficient of 0.99.
建立了一种气相色谱串联质谱法同时测定黑胡椒中的133种农药。与多步方法相比,优先采用QuEChERS(快速、简便、廉价、有效、耐用且安全)样品制备方法。提取采用乙腈进行,随后使用石墨化碳、伯仲胺和十八烷基硅烷(C18)进行净化。即使经过净化,非挥发性共提取物仍会附着在衬管和色谱柱上,从而影响仪器性能,挥发性共提取物会通过提高分析物浓度影响分析。因此,我们评估了一种稀释程序以克服这些缺点。对于稀释五十倍的样品提取物,当信噪比≥10时,定量限达到0.01 mg/kg。加标样品在0.01、0.025和0.05 mg/kg水平下的回收率在70%至120%之间,相应的精密度在3%至16%相对标准偏差之间。七级校准曲线的回归系数为0.99。