Nolst Trenité G J, Verwoerd C D, Verwoerd-Verhoef H L
Dept. of Otorhinolaryngology, Bergweg Hospital, Rotterdam, The Netherlands.
Rhinology. 1988 Mar;26(1):25-32.
A series of experiments were carried out on growing rabbits to investigate the effect of rotation (through 90 degrees and 180 degrees) or crushing of autologous cartilage implants on growth of the nose. Reconstruction of the nasal septum with rotated or crushed implants did not restore the normal growth of the nose. This is in accordance with the results of a previously described experiment in which the continuity was repaired with autologous cartilage in the same position (Nolst Trenité et al., 1987). The crushed cartilage implants were as effective as the noncrushed implants in preventing septal perforations. The implants rotated through 90 degrees, showed less intrinsic growth in dorso-ventral direction.
对生长中的兔子进行了一系列实验,以研究自体软骨植入物旋转(90度和180度)或挤压对鼻生长的影响。用旋转或挤压的植入物重建鼻中隔并不能恢复鼻子的正常生长。这与先前描述的实验结果一致,在该实验中,在相同位置用自体软骨修复连续性(诺尔斯·特里内特等人,1987年)。挤压的软骨植入物在预防鼻中隔穿孔方面与未挤压的植入物一样有效。旋转90度的植入物在背腹方向显示出较少的内在生长。