利用定量眼压计对健康人眨眼时泪液动力学的时间分析。

Chronologic Analysis of Tear Dynamics on Blinking Using Quantitative Manometry in Healthy Humans.

机构信息

Department of Ophthalmology, Osaka Medical College, Takatsuki-City, Osaka, Japan.

出版信息

Ophthalmic Plast Reconstr Surg. 2022;38(1):22-28. doi: 10.1097/IOP.0000000000001962.

Abstract

PURPOSE

To analyze the tear dynamics during blinking by measuring the inner pressure of the upper lacrimal drainage system.

METHODS

This observational study involved 11 healthy bi- or tricenarian volunteers. Direct manometry was performed using a fiber optic pressure sensor inserted into the conjunctival sac, upper/lower canaliculus (5 mm from punctum), and inferior lacrimal sac (15 mm from punctum) during both involuntary and intentional tight blinking. Pressure was measured 200 times/second during 3 separate blinks and then chronologically analyzed.

RESULTS

In all subjects of all locations during both types of blinking, the inner pressures during the stationary eyelid closing/opening were positive/approximately zero, while a positive/negative pressure spike was observed during the eyelid closing/opening movement. The averages of the maximum pressure in the spike during the intentional tight blinking (tPmax: mm Hg) in the conjunctival sac, upper/lower canaliculus, and lacrimal sac were 8.00, 12.39/12.93, and 10.59, respectively, while for the minimum (tPmin: mm Hg), the pressures were -3.18, -3.91/-3.43, and -3.31, respectively. The tPmax and tPmin in the lacrimal duct were positively correlated with that of the conjunctival sac, which suggested synchronism of the drainage system. However, the tPmax in the canaliculus was significantly higher than that of the conjunctival sac, which suggested that tears do not flow from the conjunctival sac into the lacrimal duct during eyelid closure.

CONCLUSIONS

The upper lacrimal drainage system functions as one united lumen in the lacrimal pump. The positive /negative pressure spike is essential for the lacrimal pump to efficiently eject/aspirate the tear from the lacrimal/conjunctival sac.

摘要

目的

通过测量上泪液引流系统的内压来分析眨眼过程中的泪液动力学。

方法

本观察性研究纳入了 11 名健康的双或三旬志愿者。在非自愿性和自愿性紧密眨眼期间,使用插入结膜囊、上下泪小管(距泪点 5mm)和下泪囊(距泪点 15mm)的光纤压力传感器进行直接眼压测量。在 3 次单独眨眼期间,以 200 次/秒的速度进行测量,然后进行时间顺序分析。

结果

在所有受试者的所有位置,在两种眨眼类型中,静止眼睑关闭/打开时的内压为正/接近零,而在眼睑关闭/打开运动时观察到正/负压尖峰。在自愿性紧密眨眼期间,尖峰中最大压力的平均值(tPmax:mmHg)在结膜囊、上下泪小管和泪囊中分别为 8.00、12.39/12.93 和 10.59,而最小压力(tPmin:mmHg)分别为-3.18、-3.91/-3.43 和-3.31。泪道中的 tPmax 和 tPmin 与结膜囊中相应的值呈正相关,这表明引流系统同步性。然而,泪小管中的 tPmax 明显高于结膜囊中相应的值,这表明在眼睑关闭时,泪液不会从结膜囊中流入泪道。

结论

上泪液引流系统在泪液泵中作为一个统一的腔室起作用。正/负压尖峰对于泪液泵有效地从泪囊/结膜囊中排出/抽吸泪液至关重要。