Shaikh Irshad N, Ahammed M Mansoor
Civil Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat, 395007, India.
Environ Sci Pollut Res Int. 2021 Jul;28(28):38209-38223. doi: 10.1007/s11356-021-13413-8. Epub 2021 Mar 16.
A long-duration laboratory study spanning more than 6 months was conducted to evaluate the effect of operating mode on the performance of sand filters for greywater treatment. Performance of saturated and unsaturated filters operated in continuous or intermittent mode was evaluated using settled real greywater. Effects of pause period and higher loading rate on their performance were also evaluated. Furthermore, the effect of the depth of the filter medium on the performance of the filters was also assessed. The saturated filters operated continuously or intermittently performed significantly better than the respective unsaturated filters. Saturated continuous (SC) and unsaturated intermittent (UI) filters were the best and worst performers amongst the different filters. SC filter removed on an average 98% turbidity, 76% BOD, 88% COD, 84% ammonia-N (NH-N) and 95% phosphate (PO-P). Up to 99.68% (2.40 log) removal of faecal coliforms was also achieved by this filter. SC filter showed stable and reliable performance as its effluent quality was insensitive to fluctuations in influent quality. The pause period significantly affected the removal of some of the parameters. Doubling the hydraulic loading rate significantly affected the performance of continuous filters. Though most of the pollutant removal occurred in the top 10 cm in all the filters, a depth of 50 cm was found optimum for the removal of different pollutants. Whilst all the filters produced effluent conforming to different reuse standards except microbial standards, saturated continuous filter (SC) could also meet the faecal coliform standards towards the end of the filter operation.
开展了一项为期6个多月的长期实验室研究,以评估运行模式对用于灰水处理的砂滤器性能的影响。使用沉淀后的实际灰水评估了以连续或间歇模式运行的饱和和不饱和滤器的性能。还评估了暂停期和较高负荷率对其性能的影响。此外,还评估了滤料深度对滤器性能的影响。连续或间歇运行的饱和滤器的性能明显优于各自对应的不饱和滤器。在不同滤器中,饱和连续(SC)滤器表现最佳,不饱和间歇(UI)滤器表现最差。SC滤器平均去除98%的浊度、76%的生化需氧量、88%的化学需氧量、84%的氨氮(NH-N)和95%的磷酸盐(PO-P)。该滤器对粪大肠菌群的去除率高达99.68%(2.40对数)。SC滤器的出水水质对进水水质波动不敏感,表现出稳定可靠的性能。暂停期对某些参数的去除有显著影响。将水力负荷率加倍对连续滤器的性能有显著影响。尽管所有滤器中大部分污染物的去除都发生在顶部10厘米处,但发现50厘米的深度对于去除不同污染物最为适宜。虽然除微生物标准外,所有滤器产生的出水均符合不同的回用标准,但饱和连续滤器(SC)在滤器运行末期也能达到粪大肠菌群标准。