Diabetomics, Inc., Hillsboro, OR, USA.
School of Public Health, Oregon Health & Science University, Portland, OR, USA.
J Diabetes Sci Technol. 2022 Jul;16(4):976-981. doi: 10.1177/1932296821995557. Epub 2021 Mar 17.
C-peptide is co-secreted with insulin and is not subject to hepatic clearance and thus reflects functional β-cell mass. Assessment of C-peptide levels can identify individuals at risk for or with type 1 diabetes with residual β-cell function in whom β cell-sparing interventions can be evaluated, and can aid in distinguishing type 2 diabetes from Latent Autoimmune Diabetes in Adults and late-onset type 1 diabetes. To facilitate C-peptide testing, we describe a quantitative point-of-care C-peptide test. C-peptide levels as low as 0.2 ng/ml were measurable in a fingerstick sample, and the test was accurate over a range of 0.17 to 12.0 ng/ml. This test exhibited a correlation of = 0.98 with a high-sensitivity commercial ELISA assay and a correlation of = 0.90 between matched serum and fingerstick samples.
C 肽与胰岛素一起被分泌,不受肝脏清除的影响,因此反映了功能性β细胞的数量。评估 C 肽水平可以识别出具有β细胞功能残留的 1 型糖尿病风险人群或患者,从而可以评估β细胞保护干预措施的效果,并有助于区分 2 型糖尿病、成人隐匿性自身免疫性糖尿病和迟发性 1 型糖尿病。为了便于 C 肽检测,我们描述了一种即时定量 C 肽检测方法。在指尖血样本中可检测到低至 0.2ng/ml 的 C 肽水平,并且在 0.17 至 12.0ng/ml 的范围内检测结果准确。该检测方法与高灵敏度商业 ELISA 检测方法的相关性为 = 0.98,与匹配的血清和指尖血样本的相关性为 = 0.90。