Department of Toxicology, Faculty of Pharmacy, Mersin University, Mersin, Turkey.
Department of Toxicology, Faculty of Pharmacy, Near East University, Nicosia, Cyprus.
Rapid Commun Mass Spectrom. 2021 Jun 30;35(12):e9084. doi: 10.1002/rcm.9084.
Bisphenol A (BPA), 4-t-octylphenol (4-t-OP), and 4-nonylphenol (4-NP) are ubiquitous manufactured chemicals classified as endocrine disruptors. Now these substances are prevalent and found in a wide range of biological and environmental matrices globally. Acting as xenoestrogens, their target is to bind estrogen receptors and compete against natural hormones. Thus, there is an increasing concern on their negative health consequences.
A rapid, sensitive, and robust method was established, validated, and used for the trace analysis of BPA, 4-t-OP, and 4-NP in human urine using liquid chromatography-electrospray ionization-tandem mass spectrometry.
The linear ranges for BPA, 4-t-OP, and 4-NP were 5.0-500 ng/mL. The correlation coefficient was higher than 0.996. The limit of detection and limit of quantitation for the compounds were 0.001, 0.007, and 0.005 ng/mL and 0.005, 0.023, and 0.180 ng/mL, respectively. The recoveries were as follows: 99.539%-108.557%, 97.780%-110.768%, and 99.694%-106.908% for BPA, 4-NP, and 4-t-OP respectively, with relative standard deviation <8.26%.
The established method was also applied effectively for the determination of BPA, 4-t-OP, and 4-NP levels in 15 human urine samples. This method was specifically developed for easy and precise analysis of BPA, 4-t-OP, and 4-NP in human urine. The method developed has been shown to be accurate, precise, and sensitive.
双酚 A(BPA)、4-叔辛基苯酚(4-t-OP)和 4-壬基苯酚(4-NP)是无处不在的制造化学品,被归类为内分泌干扰物。现在,这些物质在全球范围内广泛存在于各种生物和环境基质中。作为外源性雌激素,它们的作用是与雌激素受体结合并与天然激素竞争。因此,人们越来越关注它们对健康的负面影响。
建立了一种快速、灵敏、稳健的方法,并用液相色谱-电喷雾串联质谱法对人体尿液中的 BPA、4-t-OP 和 4-NP 进行痕量分析。
BPA、4-t-OP 和 4-NP 的线性范围为 5.0-500ng/mL。相关系数均大于 0.996。化合物的检出限和定量限分别为 0.001、0.007 和 0.005ng/mL 和 0.005、0.023 和 0.180ng/mL。BPA、4-NP 和 4-t-OP 的回收率分别为 99.539%-108.557%、97.780%-110.768%和 99.694%-106.908%,相对标准偏差均<8.26%。
该方法还成功应用于 15 个人体尿液样本中 BPA、4-t-OP 和 4-NP 水平的测定。该方法专门用于人体尿液中 BPA、4-t-OP 和 4-NP 的简便、精确分析。所开发的方法已被证明是准确、精密和灵敏的。