Suppr超能文献

DOAC 检测条在尿液中直接口服抗凝剂检测中的性能特征。

Performance Characteristics of DOAC Dipstick in Determining Direct Oral Anticoagulants in Urine.

机构信息

Ruprecht-Karls-University, Heidelberg, Germany.

DOASENSE GmbH, Heidelberg, Germany.

出版信息

Clin Appl Thromb Hemost. 2021 Jan-Dec;27:1076029621993550. doi: 10.1177/1076029621993550.

Abstract

Testing for direct oral anticoagulants (DOACs) in patient urine may facilitate medical treatment decisions. The aim of this study was to investigate interobserver variability by 2 independent observers compared to laboratory staff in the visual interpretation of factor Xa (DXI) and thrombin inhibitors (DTI) using the DOAC Dipstick test. We also examined whether test pads reacted to other anticoagulants and abnormal urine colors. The colors of the DOAC Dipstick direct factor Xa inhibitor and thrombin inhibitor pads were interpreted with 100% accuracy (95% confidence interval 0.862 to 1.000) for urine samples from persons treated with apixaban (n = 26), rivaroxaban (n = 24), and dabigatran (n = 29) and without anticoagulant therapy (n = 29). The factor Xa and thrombin inhibitor pads did not interact with heparin, nadroparin, fondaparinux, or coumadin. One µg/mL r-Hirudin and 6 µg/mL argatroban interacted with the DTI pad; however, this is unlikely to cause clinical problems because dabigatran is unlikely to be administered together with r-Hirudin and argatroban in clinical circumstances. Abnormal urine color was reliably detected by the urine color pad, so can prevent false interpretation of the DOAC Dipstick pad colors. In conclusion, we have demonstrated that interobserver variability when interpreting the DOAC Dipstick test strip is low and that factor Xa and thrombin inhibitor pads do not react to other anticoagulants such as heparins and coumadin. R-Hirudin and argatroban can be detected by the thrombin inhibitor pad and abnormal urine colors can be detected by the urine color pad to prevent false interpretation of the results in patient urine samples.

摘要

检测患者尿液中的直接口服抗凝剂(DOAC)可能有助于医疗决策。本研究的目的是通过 2 名独立观察者与实验室工作人员比较,用 DOAC 检测条检测 Xa 因子(DXI)和凝血酶抑制剂(DTI),观察视觉解释的观察者间变异性。我们还检查了测试垫是否会对其他抗凝剂和异常尿液颜色产生反应。阿哌沙班(n = 26)、利伐沙班(n = 24)和达比加群(n = 29)治疗者以及无抗凝治疗者(n = 29)的尿液样本中,DOAC 检测条直接 Xa 因子抑制剂和凝血酶抑制剂垫的颜色解读准确率为 100%(95%置信区间 0.862 至 1.000)。肝素、那屈肝素、磺达肝癸钠和华法林不会与 Xa 因子和凝血酶抑制剂垫相互作用。1μg/mL r-水蛭素和 6μg/mL 阿加曲班与 DTI 垫相互作用;然而,这不太可能引起临床问题,因为在临床情况下,达比加群不太可能与 r-水蛭素和阿加曲班一起给药。尿液颜色垫可靠地检测到异常尿液颜色,因此可以防止对 DOAC 检测条垫颜色的错误解读。总之,我们已经证明,在解释 DOAC 检测条试验时,观察者间的变异性较低,并且 Xa 因子和凝血酶抑制剂垫不会与肝素和华法林等其他抗凝剂发生反应。r-水蛭素和阿加曲班可以被凝血酶抑制剂垫检测到,异常尿液颜色可以被尿液颜色垫检测到,以防止对患者尿液样本结果的错误解读。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a554/7983466/7691b4b1009f/10.1177_1076029621993550-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验