单纯射频消融术比镇痛治疗更能显著改善功能:一项前瞻性病例系列研究。

Simplicity Radiofrequency Ablation Demonstrates Greater Functional Improvement Than Analgesia: A Prospective Case Series.

机构信息

Department of Rehabilitation Medicine, UT Health San Antonio, San Antonio, TX.

Department of Anesthesiology, UT Health San Antonio, San Antonio, TX.

出版信息

Pain Physician. 2021 Mar;24(2):E185-E190.

Abstract

BACKGROUND

Pain originating from the posterior sacroiliac complex is notoriously difficult to effectively treat due to its complex anatomy and variable innervation. Data on radiofrequency ablation (RFA) is limited. The Abbott Simplicity probe creates 3 monopolar lesions along the medial aspect of the sacroiliac joint and 2 bipolar lesions between the active portions of the probe. This device has been studied previously with improvement of pain-associated disability and pain reduction, but insufficient data is present to determine its utility at this time. Using the most recent literature for the potential innervation of the posterior sacroiliac joint, it is reasonable to explore this novel device and its ability to treat sacroiliac joint pain.

OBJECTIVES

Identify the percentage of improved posterior sacroiliac complex pain and improved function in patients who completed posterior sacroiliac complex radiofrequency ablation using the Simplicity probe.

STUDY DESIGN

Prospective case series.

SETTING

A single outpatient pain clinic.

METHODS

This prospective case-series occurred at an outpatient pain clinic. Data were analyzed after completion of follow-up appointments. Inclusion criteria included 2 successful lateral branch blocks. Fourteen patients with posterior sacroiliac complex pain were examined and completed sacroiliac ablation with the Simplicity probe. The numeric rating scale and the Modified Oswestry Disability Index were used as outcome measures for pain and function, respectively. The primary outcome measures were improvement in the numeric rating scale score by a reduction of 2.5 points and an improvement in Modified Oswestry Disability Index by 15% based upon previous studies demonstrating these values as the minimal clinical important difference . Patients were followed at a 3 to 6 month interval and 12 month interval (an average of 88 and 352 days, respectively).

RESULTS

In total, 14 patients were examined. At the first follow-up, 29% of patients had analgesia and 38% functionally improved. At the second follow-up, 15% of patients had analgesia and 31% functionally improved.

LIMITATIONS

Considering data were collected retrospectively, this study relied on completed charts. Therefore, data points of interest were limited to what was previously documented, which included multiple answers or the absence of numerical data points. In addition, patients were disproportionately female (71.4%). Data were also affected by patients lost to follow-up. Also, this study examined a relatively small number of patients, therefore the results should be carefully considered.

CONCLUSIONS

Radiofrequency ablation of the posterior sacroiliac complex with the Simplicity probe resulted in more functional improvement than analgesia. This study provides more data for clinicians to utilize in managing posterior sacroiliac complex pain. IRB: Protocol number 20170342HU. Not registered in clinical trials.

摘要

背景

由于其复杂的解剖结构和多变的神经支配,源自后骶髂复合体的疼痛很难有效治疗,这是众所周知的。射频消融(RFA)的数据有限。Abbott Simplicity 探针在骶髂关节的内侧形成 3 个单极损伤,在探针的活动部分之间形成 2 个双极损伤。该设备以前曾研究过,可改善与疼痛相关的残疾和减轻疼痛,但目前提供的数据不足以确定其此时的效用。根据后骶髂复合体潜在神经支配的最新文献,探索这种新型设备及其治疗骶髂关节疼痛的能力是合理的。

目的

确定使用 Simplicity 探针完成后骶髂复合体射频消融术的患者中,后骶髂复合体疼痛和功能改善的百分比。

研究设计

前瞻性病例系列。

设置

单门诊疼痛诊所。

方法

这项前瞻性病例系列研究在一家门诊疼痛诊所进行。在完成随访预约后进行数据分析。纳入标准包括 2 次成功的外侧支阻滞。对 14 名患有后骶髂复合体疼痛的患者进行检查,并使用 Simplicity 探针完成骶髂关节消融。数字评分量表和改良 Oswestry 残疾指数分别用作疼痛和功能的主要结局指标。主要结局指标是数字评分量表评分降低 2.5 分和改良 Oswestry 残疾指数提高 15%,这是基于先前的研究,表明这些值是最小临床重要差异。患者在 3 至 6 个月和 12 个月的间隔内(平均分别为 88 和 352 天)进行随访。

结果

总共有 14 名患者接受了检查。在第一次随访时,29%的患者有镇痛作用,38%的患者功能改善。在第二次随访时,15%的患者有镇痛作用,31%的患者功能改善。

局限性

考虑到数据是回顾性收集的,因此本研究依赖于已完成的图表。因此,感兴趣的数据点仅限于之前记录的内容,其中包括多个答案或缺乏数值数据点。此外,患者中女性比例过高(71.4%)。数据还受到失访患者的影响。此外,本研究检查的患者数量相对较少,因此结果应谨慎考虑。

结论

使用 Simplicity 探针对后骶髂复合体进行射频消融治疗,功能改善的效果优于镇痛效果。本研究为临床医生管理后骶髂复合体疼痛提供了更多数据。IRB:方案编号 20170342HU。未在临床试验中注册。