Aesthet Surg J. 2021 Jul 14;41(8):NP1036-NP1043. doi: 10.1093/asj/sjab143.
To date, studies on periareolar dermis release have recorded the areola sensitivity as a mean. Despite being clinically reported by patients, specific points of the areola may present sensitivities not detected when researchers only consider mean values.
The aim of this study was to determine the pressure sensitivity at specific points of the nipple-areola complex and compare these values with the mean value measured in the areolas of patients undergoing reduction mammaplasty with periareolar dermis release.
This is a prospective, randomized controlled trial of 39 consecutive patients (78 breasts) who underwent surgery for treatment of breast hypertrophy; the same surgical technique was used for all patients. In each patient, 1 breast was assigned to a control group and the other to an experimental group. The periareolar dermis release was performed in the experimental group (39 breasts). Pressure sensitivity was tested with Semmes-Weinstein monofilaments on the papilla and at 4 specific points of the areola. The evaluations were conducted preoperatively and at 3 weeks, 6 weeks, and 1 year postoperatively.
The group comparisons show a statistically significant difference in sensitivity at the medial point of the areola and in the papilla at 3 weeks postoperation. This difference disappeared in the 1-year evaluation. This recovery profile also occurs when areola sensitivity corresponds to a mean value. The sensitivity significantly decreased at the lower point of the areola up to 1 year postoperation in the control and experimental groups.
The periareolar dermis release did not compromise the pressure sensitivity at the points evaluated in the nipple-areola complex. The mean areola sensitivity differed from the sensitivity at the lower point of the areola.
迄今为止,有关乳晕真皮释放的研究均以均值记录乳晕敏感性。尽管患者在临床上有报告,但当研究人员仅考虑均值时,乳晕的某些特定部位可能会出现未被检测到的敏感性。
本研究旨在确定乳头乳晕复合体特定部位的压力敏感性,并将这些值与接受乳晕真皮释放的缩乳术患者乳晕的均值进行比较。
这是一项连续 39 例(78 侧乳房)患者接受手术治疗乳房肥大的前瞻性随机对照试验;所有患者均采用相同的手术技术。在每个患者中,一侧乳房被分配到对照组,另一侧乳房被分配到实验组。实验组(39 侧乳房)进行乳晕真皮释放。使用 Semmes-Weinstein 单丝测试乳头和乳晕的 4 个特定部位的压力敏感性。术前和术后 3 周、6 周和 1 年进行评估。
组间比较显示,术后 3 周时乳晕内中点和乳头的敏感性存在统计学显著差异。这种差异在 1 年评估时消失。当乳晕敏感性对应均值时,也会出现这种恢复模式。在对照组和实验组中,乳晕下点的敏感性在术后 1 年内显著下降。
乳晕真皮释放不会影响乳头乳晕复合体评估点的压力敏感性。乳晕平均敏感性与乳晕下点的敏感性不同。