Suppr超能文献

左侧先天性膈疝胎儿磁共振成像中肺和肝体积测量的可重复性。

Reproducibility of Lung and Liver Volume Measurements on Fetal Magnetic Resonance Imaging in Left-Sided Congenital Diaphragmatic Hernia.

机构信息

Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA.

Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA.

出版信息

Fetal Diagn Ther. 2021;48(4):258-264. doi: 10.1159/000512491. Epub 2021 Mar 23.

Abstract

INTRODUCTION

Congenital diaphragmatic hernia (CDH) affects 1 in 3,000 live births and is associated with significant morbidity and mortality.

METHODS

A review of fetal magnetic resonance imaging (MRI) examinations was performed for fetuses with left CDH and normal lung controls. Image review and manual tracings were performed by 4 pediatric radiologists; right and left lung volumes in the coronal and axial planes as well as liver volume above and below the diaphragm in the coronal plane were measured. Intra- and interreviewer reproducibility was assessed using intraclass correlation coefficient (ICC) and Bland-Altman analysis.

RESULTS

Excellent intra- and interreviewer reproducibility of the right and left lung volume measurements was observed in both axial planes (interreviewer ICC: right lung: 0.97, 95% CI: 0.95-0.99; left lung: 0.97, 95% CI: 0.95-0.98) and coronal planes (interreviewer ICC: right lung: 0.97, 95% CI: 0.95-0.98; left lung: 0.96, 95% CI: 0.93-0.98). Moderate-to-good interreviewer reproducibility was observed for liver volume above the diaphragm (ICC 0.7, 95% CI: 0.59-0.81). Liver volume below the diaphragm had a good-to-excellent interreviewer reproducibility (ICC 0.88, 95% CI: 9.82-0.93).

CONCLUSIONS

The present study demonstrated an excellent intra- and interreviewer reproducibility of MRI lung volume measurements and good-to-moderate inter- and intrareviewer reproducibility of liver volume measurements after standardization of the methods at our fetal center.

摘要

介绍

先天性膈疝(CDH)影响每 3000 例活产中的 1 例,与显著的发病率和死亡率相关。

方法

对左侧 CDH 胎儿和正常肺对照胎儿的胎儿磁共振成像(MRI)检查进行了回顾。由 4 名儿科放射科医生进行图像回顾和手动描记;在冠状面和轴面测量右肺和左肺容积,以及在冠状面测量膈肌上下的肝体积。使用组内相关系数(ICC)和 Bland-Altman 分析评估内部和内部审查者的可重复性。

结果

在轴面和冠状面均观察到右肺和左肺容积测量的内部和内部审查者具有极好的可重复性(轴面:内部审查者 ICC:右肺 0.97,95%CI:0.95-0.99;左肺 0.97,95%CI:0.95-0.98;冠状面:内部审查者 ICC:右肺 0.97,95%CI:0.95-0.98;左肺 0.96,95%CI:0.93-0.98)。膈肌上肝体积的可重复性为中等至良好(ICC 0.7,95%CI:0.59-0.81)。膈肌下肝体积的可重复性为良好至极好(ICC 0.88,95%CI:0.92-0.93)。

结论

本研究在我们的胎儿中心对方法进行标准化后,证明了 MRI 肺容积测量的极好的内部和内部审查者的可重复性,以及肝容积测量的良好至中等的内部和内部审查者的可重复性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验