Suppr超能文献

即刻加载 3 毫米长微螺钉种植体的稳定性:一项可行性研究。

Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study.

机构信息

Private practice (Dallas/TX, USA).

Texas A&M University, College of Dentistry, Department of Orthodontics (Dallas/TX, USA).

出版信息

Dental Press J Orthod. 2021 Mar 22;26(1):e2119155. doi: 10.1590/2177-6709.26.1.e2119155.oar. eCollection 2021.

Abstract

INTRODUCTION

Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient.

OBJECTIVE

To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician.

METHODS

82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort.

RESULTS

The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only.

CONCLUSIONS

Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary.

摘要

引言

为了使正畸更有效和高效,需要使用更短的微型种植体(MSI)。

目的

评估新手临床医生在人类中植入的 3 毫米长 MSI 的稳定性、插入扭矩、移除扭矩和疼痛。

方法

将 82 个 MSI 植入 26 名成人的上颌颊侧。一对相邻的植入物立即加载 100g。在 1、3、5 和 8 周后召回受试者,以验证稳定性并完成与 MSI 相关的疼痛和不适的调查问卷。

结果

总体失败率为 32.9%。前牙和后牙 MSI 的失败率分别为 35.7%和 30.0%。排除 10 个(12.2%)因创伤而脱位的 MSI,前牙和后牙的失败率分别为 30.1%和 15.2%,总体初级失败率为 23.6%。在前 41 个 MSI 中,失败率明显(p=0.010)更高(46.3%比后 41 个 MSI 的 19.5%)。排除创伤性丢失的 MSI,失败发生在第 42 天之前。受试者仅在第一周经历非常低的疼痛(2.2%的最大值)和不适(5.5%的最大值)。

结论

由新手操作的更短的 3 毫米 MSI 极有可能失败。然而,随着 MSI 植入数量的增加,失败率可以在很长一段时间内大大降低。植入 3 毫米 MSI 后经历的疼痛和不适是轻微和暂时的。