Suppr超能文献

磁共振成像在牙髓内视镜引导下的适用性:原理验证。

Suitability of Magnetic Resonance Imaging for Guided Endodontics: Proof of Principle.

机构信息

Department of Periodontology, Endodontology and Cariology, University Center for Dental Medicine, University of Basel, Basel, Switzerland.

Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland.

出版信息

J Endod. 2021 Jun;47(6):954-960. doi: 10.1016/j.joen.2021.03.011. Epub 2021 Mar 26.

Abstract

INTRODUCTION

This proof-of-principle study aimed to demonstrate that magnetic resonance imaging (MRI) is sufficiently accurate for the detection of root canals using guided endodontics.

METHODS

One hundred extracted human teeth (anterior and premolar) were mounted onto 5 mandibular and 5 maxillary models, fitted with splints designed to accommodate a thin layer of aqueous gel for indirect imaging, and scanned by MRI. After MRI and intraoral scans were aligned using planning software, access cavities were planned virtually, and templates were manufactured with computer-aided design/computer-aided manufacturing, the access cavities were prepared. Cone-beam computed tomographic scans were performed and matched with the virtual preoperative planning data to determine the accuracy of access cavity preparation in terms of deviation between planned and prepared cavities in the mesiodistal and buccolingual dimensions and angle. Descriptive statistical analysis was performed, and the mean values were compared using the t test.

RESULTS

Ninety-one of 100 root canals were successfully scouted after MRI-guided access cavity preparation. The mean angle deviation was 1.82°. The mean deviation ranged from 0.21-0.31 mm at the base of the bur and from 0.28-0.44 mm at the tip of the bur. Preparation in the buccolingual dimension was significantly more precise in mandibular compared with maxillary teeth, and accuracy in the mesiodistal dimension was more precise in anterior teeth compared with premolars.

CONCLUSIONS

This in vitro study demonstrated the suitability of MRI for guided endodontic access cavity preparation.

摘要

简介

本原理验证研究旨在证明磁共振成像(MRI)在使用引导式牙髓学检测根管时具有足够的准确性。

方法

将 100 颗离体人牙(前牙和前磨牙)安装在 5 个下颌和 5 个上颌模型上,这些模型配备了适合薄水凝胶层的夹板,用于间接成像,并通过 MRI 进行扫描。在 MRI 和口腔内扫描使用规划软件对齐后,虚拟规划了进入腔室,并使用计算机辅助设计/计算机辅助制造制造了模板,然后制备进入腔室。进行了锥形束计算机断层扫描,并与虚拟术前规划数据进行匹配,以确定进入腔室制备在近远中尺寸和颊舌角度方面的计划腔室和制备腔室之间的偏差的准确性。进行了描述性统计分析,并使用 t 检验比较了平均值。

结果

在 MRI 引导的进入腔室制备后,成功探查了 100 个根管中的 91 个。平均角度偏差为 1.82°。偏差的平均值在钻头底部为 0.21-0.31 毫米,在钻头尖端为 0.28-0.44 毫米。与上颌牙齿相比,下颌牙齿的颊舌尺寸制备更精确,与前磨牙相比,近远中尺寸的准确性更高。

结论

这项体外研究表明 MRI 适合引导式牙髓进入腔室制备。