Suppr超能文献

使用数字和传统技术进行牙合记录精度的临床评估。

Clinical evaluation of the precision of interocclusal registration by using digital and conventional techniques.

机构信息

Predoctoral student, Department of Prosthodontics, School of Dentistry, Showa University, Tokyo, Japan.

Assistant Professor, Department of Prosthodontics, School of Dentistry, Showa University, Tokyo, Japan.

出版信息

J Prosthet Dent. 2022 Oct;128(4):611-617. doi: 10.1016/j.prosdent.2021.01.021. Epub 2021 Mar 26.

Abstract

STATEMENT OF PROBLEM

Although studies have evaluated the accuracy of data obtained by intraoral scanners (IOSs), studies on the precision of interocclusal registrations made with IOSs are lacking.

PURPOSE

The purpose of this clinical study was to compare the precision of IOS interocclusal registration with that of conventional methods with a silicone impression material and a gypsum cast.

MATERIAL AND METHODS

Eight participants with complete natural dentitions were enrolled. Images of their maxillary and mandibular quadrant arches and their interocclusal relationship were scanned with 2 IOSs: the 3M True Definition Scanner and the TRIOS Scanner 3. In the conventional method, impressions of complete-arch dentition and quadrant-arch dentition were made with a silicone impression material, and gypsum casts were fabricated, mounted on a dental articulator related with a silicone interocclusal record, and scanned with a 3D laboratory scanner. These procedures were repeated 4 times, and 4 sets of interocclusal registration data in standard tessellation language (STL) format were generated for each condition. Interocclusal registration precision was evaluated by determining the discrepancy of the STL data between repeated measurements by using the best-fit-algorithm method.

RESULTS

The average discrepancies for all participants were 25 ±12 μm for the True Definition, 31 ±7 μm for the TRIOS 3, 154 ±59 μm for the complete arch, and 128 ±33 μm for the quadrant arch. The Kruskal-Wallis test revealed that the effect of the impression methods on the discrepancy was statistically significant (P<.001). The Steel-Dwass test showed that both digital scan methods exhibited significantly smaller discrepancies than the 2 conventional methods (P=.005).

CONCLUSIONS

These results suggest that the intermaxillary relationship captured by the digital scan method by using IOSs had better precision than that obtained by the conventional method.

摘要

问题陈述

尽管已经有研究评估了口内扫描仪(IOS)获取的数据的准确性,但缺乏关于 IOS 进行的咬合记录的精度的研究。

目的

本临床研究的目的是比较 IOS 咬合记录与使用硅橡胶印模材料和石膏模型的传统方法的精度。

材料和方法

纳入了 8 名具有完整天然牙列的参与者。使用 2 种 IOS(3M True Definition Scanner 和 TRIOS Scanner 3)扫描上颌和下颌象限弓及其咬合关系的图像。在传统方法中,使用硅橡胶印模材料制作全牙弓和象限牙弓的印模,并制作石膏模型,将其安装在与硅橡胶咬合记录相关的牙合架上,并使用 3D 实验室扫描仪进行扫描。这些程序重复进行了 4 次,为每个条件生成了 4 组标准 tessellation language(STL)格式的咬合记录数据。通过使用最佳拟合算法方法确定重复测量之间的 STL 数据差异来评估咬合记录精度。

结果

对于所有参与者,True Definition 的平均差异为 25 ±12 μm,TRIOS 3 的平均差异为 31 ±7 μm,全牙弓的平均差异为 154 ±59 μm,象限牙弓的平均差异为 128 ±33 μm。Kruskal-Wallis 检验显示,印模方法对差异的影响具有统计学意义(P<.001)。Steel-Dwass 检验表明,两种数字扫描方法的差异均明显小于两种传统方法(P=.005)。

结论

这些结果表明,使用 IOS 的数字扫描方法获取的颌间关系的精度优于传统方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验