Heart Vessels. 2021 Nov;36(11):1694-1700. doi: 10.1007/s00380-021-01843-w. Epub 2021 Mar 29.

Abstract

In Italy, a strict lockdown was imposed from 8 March 2020 to stop the spread of the coronavirus disease 2019 (COVID-19). We explored the effect of this lockdown on data transmitted by remote monitoring (RM) of implantable cardioverter and cardiac resynchronization therapy defibrillators (ICDs/CRT-Ds). RM daily transmissions from ICDs and CRT-Ds were analyzed and compared in two consecutive 1 month frames pre and post-lockdown: period I (7 February-7 March 2020) and period II (8 March-7 April 2020). The study cohort included 180 patients (81.1% male, 63.3% ICDs and 36.7% CRT-Ds) with a median age of 70 (interquartile range 62-78) years. The median value of physical activity provided by accelerometric sensors showed a significant reduction between period I and II [13.1% (8.2-18.1%) versus 9.4% (6.3-13.8%), p < 0.001]. Eighty nine % of patients decreased their activity, for 43.3% the relative reduction was ≥ 25%. The mean heart rate decreased significantly [69.2 (63.8-75.6) bpm vs 67.9 (62.7-75.3) bpm, p < 0.001], but with greater reduction (≈3 beats/minute) in patients aged < 70 years. Resting heart rate and thoracic impedance showed minor variations. No differences were observed in device pacing % and arrhythmias. In cardiac patients, the lockdown imposed to contain COVID-19 outbreak significantly reduced the amount of physical activity and the mean heart rate. These side effects of in-home confinement quarantine should be taken in consideration for frail patients.

摘要

在意大利,为了阻止 2019 年冠状病毒病(COVID-19)的传播,从 2020 年 3 月 8 日起实施了严格的封锁措施。我们探讨了这一封锁措施对植入式心脏转复除颤器(ICD)和心脏再同步治疗除颤器(CRT-D)远程监测(RM)传输数据的影响。对 ICD 和 CRT-D 的 RM 每日传输进行了分析,并在封锁前后连续两个 1 个月的时间段内进行了比较:第 I 期(2020 年 2 月 7 日至 3 月 7 日)和第 II 期(2020 年 3 月 8 日至 4 月 7 日)。研究队列包括 180 名患者(81.1%为男性,63.3%为 ICD,36.7%为 CRT-D),中位年龄为 70 岁(四分位间距 62-78 岁)。加速度计传感器提供的身体活动中位数显著减少,从第 I 期到第 II 期分别为 13.1%(8.2-18.1%)和 9.4%(6.3-13.8%)(p<0.001)。89%的患者减少了活动,其中 43.3%的相对减少量≥25%。平均心率显著下降[69.2(63.8-75.6)次/分比 67.9(62.7-75.3)次/分,p<0.001],但年龄<70 岁的患者下降幅度更大(≈3 次/分钟)。静息心率和胸阻抗变化较小。设备起搏%和心律失常无差异。在心脏患者中,为遏制 COVID-19 爆发而实施的封锁措施显著减少了身体活动量和平均心率。在家隔离检疫的这些副作用应引起虚弱患者的重视。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c102/8006504/69b0d51ab0b2/380_2021_1843_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验