Suppr超能文献

采用高效液相色谱-串联质谱法测定人血浆中的 21 种光引发剂:系统验证及在健康志愿者中的应用。

Determination of 21 photoinitiators in human plasma by using high-performance liquid chromatography coupled with tandem mass spectrometry: A systemically validation and application in healthy volunteers.

机构信息

Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality, Jinan University, Guangzhou 511443, China; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Science, Beijing 100085, China.

China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, 100021, China.

出版信息

J Chromatogr A. 2021 Apr 26;1643:462079. doi: 10.1016/j.chroma.2021.462079. Epub 2021 Mar 19.

Abstract

In the present study, a comprehensive and sensitive method for simultaneous determination of 21 PIs (nine benzophenones, eight amine co-initiators, and four thioxanthones) in human plasma using high-performance liquid chromatography coupled with tandem mass spectrometry was developed and validated. Two different pre-treatment approaches (liquid-liquid extraction (LLE) and LLE coupled with solid-phase extraction (SPE)) and eight extraction solvents were studied to optimize sample treatment to obtain good recoveries and reduce any matrix effects. The procedure of LLE+SPE was selected as final sample treatment procedure because it obtained higher recoveries as well as lower matrix effects than that performed by LLE alone. The recoveries of 21 target analytes at three spiked concentrations (0.05, 0.5, and 5 ng/mL) ranged from 81% to 109%. The intra- and inter-day relative standard deviations were between 2.5% and 13%. Accuracy and precision data indicated that the detection method was accurate and precise for most of the PIs. The linearities of the labeled dilution calibration curves at 10 concentration levels (iLOQ to 100 ng/mL or iLOQ to 200 ng/mL) were good with correlation coefficients ranged from 0.995 to 0.999. The method quantification limits were in the range of 1.7-16 pg/mL. The analytical method was applied to the analysis of PIs in 14 human plasma samples collected from pregnant women in Guangdong Province, China. Fifteen PIs were detected with total concentrations ranging from 318 to 2772 pg/mL. The ubiquitous contamination of human plasma with PIs suggests that there is widespread exposure to these compounds. Consequently, there should be increased awareness of these pollutants in the environment.

摘要

本研究建立并验证了一种同时测定人血浆中 21 种光引发剂(9 种二苯甲酮、8 种胺助引发剂和 4 种硫杂蒽酮)的高效液相色谱-串联质谱法。研究了两种不同的预处理方法(液-液萃取(LLE)和 LLE 结合固相萃取(SPE))和八种萃取溶剂,以优化样品处理,获得良好的回收率并减少任何基质效应。选择 LLE+SPE 程序作为最终的样品处理程序,因为它获得的回收率更高,基质效应比单独的 LLE 更低。21 种目标分析物在三个加标浓度(0.05、0.5 和 5ng/mL)下的回收率在 81%至 109%之间。日内和日间相对标准偏差在 2.5%至 13%之间。准确度和精密度数据表明,该检测方法对大多数光引发剂都准确且精密。10 个浓度水平(iLOQ 至 100ng/mL 或 iLOQ 至 200ng/mL)的标记稀释校准曲线的线性良好,相关系数在 0.995 至 0.999 之间。方法定量限在 1.7-16pg/mL 范围内。该分析方法应用于分析来自中国广东省的 14 名孕妇的人血浆中的光引发剂。检测到 15 种光引发剂,总浓度范围为 318 至 2772pg/mL。这些化合物普遍存在于人类血浆中,表明广泛接触到这些化合物。因此,应该增加对环境中这些污染物的认识。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验