Impact of anatomical variations on ultrasonographic reference values of lower extremity peripheral nerves.

机构信息

Department of Clinical Neuroscience and Therapeutics, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.

出版信息

Muscle Nerve. 2021 Jun;63(6):890-896. doi: 10.1002/mus.27238. Epub 2021 Apr 16.

Abstract

INTRODUCTION/AIMS: Cross-sectional area (CSA) reference values using ultrasonography vary widely for lower extremity peripheral nerves. In addition, there is a lack of data on the muscular branches of the tibial nerve and the anatomical variations of the sural nerve. We aimed to evaluate the ultrasonographic reference values for lower extremity peripheral nerves considering different anatomical variations and physical factors.

METHODS

The CSA of the lower extremity nerve was measured at 10 sites. In addition to establishing reference values, differences in the CSA owing to anatomical variations were verified. The relationship between CSA and physical factors, such as age, height, weight, body mass index, and ankle circumference, was also examined.

RESULTS

A total of 100 healthy Japanese volunteers were recruited. The mean CSA of the sural nerve significantly differed depending on its formation pattern (1.4-1.8 mm ). The mean decreases in CSAs from the proximal to distal tibial and fibular nerves within the popliteal region significantly differed based on the fine branching pattern. The maximum value of the mean decreases in CSAs in the tibial and fibular nerves reached 7.2 and 2.5 mm , respectively. With respect to physical factors, age and ankle circumferences were associated with CSA at several measurement sites.

DISCUSSION

Fine branching from the tibial and fibular nerves and sural nerve formation may affect CSA measurements. The establishment of accurate CSA reference values requires consideration of anatomical variations in the peripheral nerves of the lower extremity.

摘要

简介/目的:使用超声测量下肢周围神经的横截面积(CSA)参考值差异很大。此外,关于胫神经的肌支和腓肠神经的解剖变异的数据也很少。我们旨在评估考虑到不同解剖变异和物理因素的下肢周围神经的超声参考值。

方法

在 10 个部位测量下肢神经的 CSA。除了建立参考值外,还验证了 CSA 因解剖变异而产生的差异。还检查了 CSA 与年龄、身高、体重、体重指数和踝关节周长等物理因素之间的关系。

结果

共招募了 100 名健康的日本志愿者。腓肠神经的平均 CSA 因其形成模式而异(1.4-1.8mm)。腘窝内从近端到远端胫神经和腓总神经的 CSA 均值下降差异显著,这取决于精细分支模式。胫神经和腓总神经 CSA 均值下降的最大值分别达到 7.2 和 2.5mm。就物理因素而言,年龄和踝关节周长与几个测量部位的 CSA 相关。

讨论

胫神经和腓总神经以及腓肠神经的精细分支可能会影响 CSA 测量。准确 CSA 参考值的建立需要考虑下肢周围神经的解剖变异。