Häring N, Salama Z, Reif G, Jaeger H
Analytical Research Centre of the LAB GmbH, Neu-Ulm, Fed. Rep. of Germany.
Arzneimittelforschung. 1988 Mar;38(3):404-7.
Depending on the very low therapeutic doses of clonidine and the resulting low blood levels (in the pg/ml range), for quantitative determinations in body fluids only methods of necessary selectivity as well as corresponding sensitivity can be employed successfully. Furthermore, the method should also be suited for the rapid processing of large sample numbers generated e.g. during clinical studies evaluating pharmacokinetics and/or the bioavailability/bioequivalence. Thus a gas chromatographic/mass spectrometric assay was developed employing fused-silica, bonded-phase capillary columns, chemical ionization with ammonia as a selective reagent gas in combination with the registration of preselected, characteristic negative ions (SIR, NICI) and a deuterated internal standard. Therefore, the method proves to be exceptionally selective and sensitive: a lower limit of detection of 10 pg/ml plasma is reached, the calibration curve is linear in the 25-1500 pg/ml range and the recovery from blood exceeds 90%. The assay has been successfully approved in several clinical studies, whereby especially the simple sample preparation led to very short times for analysis.
鉴于可乐定的治疗剂量极低,导致血药浓度很低(处于皮克/毫升范围),对于体液中的定量测定,只有具备必要选择性和相应灵敏度的方法才能成功应用。此外,该方法还应适用于快速处理大量样本,比如在评估药代动力学和/或生物利用度/生物等效性的临床研究过程中产生的样本。因此,开发了一种气相色谱/质谱分析法,采用熔融石英键合相毛细管柱,以氨作为选择性反应气进行化学电离,结合预选的特征负离子(选择离子监测、负离子化学电离)记录和氘代内标。因此,该方法具有极高的选择性和灵敏度:血浆检测下限达到10皮克/毫升,校准曲线在25 - 1500皮克/毫升范围内呈线性,血液回收率超过90%。该分析方法已在多项临床研究中成功获批,尤其是简单的样品制备使得分析时间非常短。