Ottoila P, Taskinen J, Sothmann A
Biomed Mass Spectrom. 1982 Mar;9(3):108-10. doi: 10.1002/bms.1200090306.
A quantitative method for determination of nitroglycerin in human plasma was developed. Nitroglycerin and the internal standard (butane-1,2,4-triyl trinitrate) were extracted from plasma with pentane. The extracts were analysed by gas chromatography mass spectrometry using fused silica capillary columns and electron capture negative ion chemical ionization. The quantitation limit of the method was about 50 pg ml-1. Linear calibration curves were obtained in the range of 50-1600 pg ml-1. Precision at the level of 100 pg ml-1 was 4%.
建立了一种测定人血浆中硝酸甘油的定量方法。用戊烷从血浆中萃取硝酸甘油和内标(1,2,4-丁三醇三硝酸酯)。萃取物采用熔融石英毛细管柱和电子捕获负离子化学电离通过气相色谱-质谱联用仪进行分析。该方法的定量限约为50 pg/ml-1。在50 - 1600 pg/ml-1范围内获得线性校准曲线。100 pg/ml-1水平的精密度为4%。