Department of Cardiology, Royal Victoria Hospital, Belfast Health and Social Care Trust, Belfast, UK.
Biomedical Sciences Research Institute, Ulster University, Coleraine, UK.
Sci Rep. 2021 Apr 7;11(1):7660. doi: 10.1038/s41598-021-87315-7.
Microcirculatory dysfunction occurs early in cardiovascular disease (CVD) development. Acute myocardial infarction (MI) is a late consequence of CVD. The conjunctival microcirculation is readily-accessible for quantitative assessment and has not previously been studied in MI patients. We compared the conjunctival microcirculation of acute MI patients and age/sex-matched healthy controls to determine if there were differences in microcirculatory parameters. We acquired images using an iPhone 6s and slit-lamp biomicroscope. Parameters measured included diameter, axial velocity, wall shear rate and blood volume flow. Results are for all vessels as they were not sub-classified into arterioles or venules. The conjunctival microcirculation was assessed in 56 controls and 59 inpatients with a presenting diagnosis of MI. Mean vessel diameter for the controls was 21.41 ± 7.57 μm compared to 22.32 ± 7.66 μm for the MI patients (p < 0.001). Axial velocity for the controls was 0.53 ± 0.15 mm/s compared to 0.49 ± 0.17 mm/s for the MI patients (p < 0.001). Wall shear rate was higher for controls than MI patients (162 ± 93 s vs 145 ± 88 s, p < 0.001). Blood volume flow did not differ significantly for the controls and MI patients (153 ± 124 pl/s vs 154 ± 125 pl/s, p = 0.84). This pilot iPhone and slit-lamp assessment of the conjunctival microcirculation found lower axial velocity and wall shear rate in patients with acute MI. Further study is required to correlate these findings further and assess long-term outcomes in this patient group with a severe CVD phenotype.
微血管功能障碍发生在心血管疾病 (CVD) 发展的早期。急性心肌梗死 (MI) 是 CVD 的晚期后果。结膜微循环易于进行定量评估,以前尚未在 MI 患者中进行过研究。我们比较了急性 MI 患者和年龄/性别匹配的健康对照者的结膜微循环,以确定微循环参数是否存在差异。我们使用 iPhone 6s 和裂隙灯生物显微镜获取图像。测量的参数包括直径、轴向速度、壁面切变率和血液体积流量。结果适用于所有血管,因为它们没有细分为小动脉或小静脉。评估了 56 名对照者和 59 名初诊为 MI 的住院患者的结膜微循环。对照组的平均血管直径为 21.41±7.57μm,而 MI 患者为 22.32±7.66μm(p<0.001)。对照组的轴向速度为 0.53±0.15mm/s,而 MI 患者为 0.49±0.17mm/s(p<0.001)。对照组的壁面切变率高于 MI 患者(162±93s 比 145±88s,p<0.001)。对照组和 MI 患者的血液体积流量无显著差异(153±124pl/s 比 154±125pl/s,p=0.84)。这项使用 iPhone 和裂隙灯评估结膜微循环的初步研究发现,急性 MI 患者的轴向速度和壁面切变率较低。需要进一步研究以进一步关联这些发现,并评估该严重 CVD 表型患者群体的长期结局。