Suppr超能文献

炎症性肠病患儿的身体成分评估:不同方法的比较。

Body composition assessment in children with inflammatory bowel disease: A comparison of different methods.

机构信息

Pediatric Gastroenterology Unit, Department of Pediatrics, University of Lausanne, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland.

Nestle Research, Nestlé Institute of Food Safety and Analytical Sciences, Lausanne, Switzerland.

出版信息

J Paediatr Child Health. 2021 Sep;57(9):1414-1419. doi: 10.1111/jpc.15491. Epub 2021 Apr 13.

Abstract

AIM

To assess different techniques to measure body composition in paediatric patients with inflammatory bowel disease using dual energy X-ray absorptiometry as a reference method. We hypothesised that a three-compartment model may demonstrate superiority over other methods as skinfold thickness equations and bioelectrical impedance analysis.

METHODS

Body composition was assessed using skinfold thickness equations, bioelectrical impedance analysis and the three-compartment model. Data obtained with these methods were compared to the results obtained by dual energy X-ray absorptiometry. Statistical analysis was performed using Spearman's correlation and Bland-Altman's limits of agreement method.

RESULTS

Twenty-one paediatric patients with inflammatory bowel disease were included: 11 females and 10 males; mean age for the entire group: 14.3 years, range 12-16 years. In children with inflammatory bowel disease, skinfold thickness equations, bioelectrical impedance analysis and the three-compartment model showed reliable measurements with small differences in the percentage of total body fat and good limits of agreements.

CONCLUSION

The assessment of body composition using bioelectrical impedance analysis provides a valid and accurate method in children with inflammatory bowel disease as compared to dual energy X-ray absorptiometry. In the future, superiority of 3-compartment model in research and clinical settings of nutritional intervention and disease status in children with inflammatory bowel disease remains to be demonstrated.

摘要

目的

使用双能 X 射线吸收法作为参考方法,评估小儿炎症性肠病患者的身体成分测量的不同技术。我们假设三 compartment 模型可能优于其他方法,如皮褶厚度方程和生物电阻抗分析。

方法

使用皮褶厚度方程、生物电阻抗分析和三 compartment 模型评估身体成分。这些方法获得的数据与双能 X 射线吸收法获得的结果进行比较。使用 Spearman 相关系数和 Bland-Altman 一致性界限方法进行统计分析。

结果

共纳入 21 例炎症性肠病患儿:女 11 例,男 10 例;整个组的平均年龄为 14.3 岁,范围为 12-16 岁。在炎症性肠病患儿中,皮褶厚度方程、生物电阻抗分析和三 compartment 模型显示出可靠的测量结果,全身脂肪百分比差异较小,一致性界限良好。

结论

与双能 X 射线吸收法相比,生物电阻抗分析在炎症性肠病患儿中评估身体成分是一种有效且准确的方法。未来,三 compartment 模型在炎症性肠病患儿营养干预和疾病状态的研究和临床中的优越性仍有待证明。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验