The SpeedWheel (SW) test is an objective test of visual acuity (VA) using suppression of the optokinetic nystagmus (OKN). Here, we established prediction intervals of the SW measures compared to Snellen acuity in adults and children.
In this prospective, single center study, subjects aged at least 4 years underwent testing of VA with SW, Landolt-C, and Tumbling-E symbols (Freiburg acuity test: FrACT-C, FrACT-E). Prediction intervals were established for SW compared to FrACT-C or -E and for FrACT-E compared to FrACT-C. Mixed linear effect models were applied for statistical analysis.
From 241 subjects, 471 eyes were included: median age 36 years, range 4 - 88 years, 43.6% male, 56.4% female. Eyes included were either healthy or had various underlying ophthalmic conditions. Prediction intervals for SW to estimate FrACT-C or -E acuity showed a similar range compared to the prediction interval of FrACT-C for the estimation of FrACT-E acuity. For each acuity step, there was no influence of age. Up to an SW acuity of 0.7 logMAR, 80% of the subjects had a FrACT-C acuity that was at most 1.6 logMAR lines below, and for an SW acuity of 1.0 logMAR, FrACT-C acuity was not worse than 4 logMAR lines. Prediction intervals for eyes with refractive error, cataract, visual field loss and retinal disease did not differ significantly from healthy eyes in contrast to eyes with amblyopia or multiple ophthalmic disorders. SW correlated well to FrACT tests and results of a previous study fell within our prediction estimates.
Our prediction intervals for SW acuity may be used to estimate Snellen acuity (FrACT-C and -E) in the clinic in adults and children unable to cooperate in other acuity testing.
SpeedWheel(SW)测试是一种使用视动性眼球震颤(OKN)抑制的客观视力(VA)测试。在这里,我们建立了 SW 测量值与成年人和儿童 Snellen 视力之间的预测区间。
在这项前瞻性、单中心研究中,至少 4 岁的受试者接受了 SW、Landolt-C 和 Tumbling-E 符号(Freiburg 视力测试:FrACT-C、FrACT-E)的 VA 测试。建立了 SW 与 FrACT-C 或 -E 以及 FrACT-E 与 FrACT-C 之间的预测区间。应用混合线性效应模型进行统计分析。
从 241 名受试者中,纳入了 471 只眼:中位年龄 36 岁,范围 4-88 岁,男性 43.6%,女性 56.4%。纳入的眼睛要么健康,要么有各种眼部疾病。SW 预测区间用于估计 FrACT-C 或 -E 视力的范围与 FrACT-C 用于估计 FrACT-E 视力的预测区间相似。对于每个视力阶段,年龄均无影响。在 SW 视力达到 0.7 logMAR 之前,80%的受试者的 FrACT-C 视力最多低 1.6 logMAR 线,而在 SW 视力达到 1.0 logMAR 时,FrACT-C 视力不低于 4 logMAR 线。与弱视或多种眼部疾病的眼睛相比,屈光不正、白内障、视野丧失和视网膜疾病的眼睛的预测区间与健康眼睛没有显著差异。SW 与 FrACT 测试相关性良好,且之前研究的结果落在我们的预测估计范围内。
我们的 SW 视力预测区间可用于在无法进行其他视力测试的成人和儿童中,在临床中估计 Snellen 视力(FrACT-C 和 -E)。