Abstract

A simple and robust sensor (fMWCNT-Nafion®0.5%/GCE) for determination of imidacloprid (IMI), a widely used neonicotinoid, was developed using a glassy carbon electrode (GCE) modified with functionalized multi-walled carbon nanotubes (fMWCNT) and Nafion®. The obtained data suggest that IMI reduction is an irreversible process, due to the reduction of the nitro group to hydroxylamine derivatives, with the participation of two protons and four electrons, and a charge transfer coefficient of 0.141. The optimized square-wave voltammetric conditions were: McIlvaine buffer at pH 6.0, 0.5% of Nafion® in the fMWCNT suspension, -0.6 V and 180 s as accumulation potential and time, respectively. A linearity in the range of 2.00 × 10-7 to 1.77 × 10-6 mol L-1 IMI, with the values of limit of detection and limit of quantification were equal to 3.74 × 10-8 mol L-1 and 1.25 × 10-7 mol L-1, respectively. Repeatability and reproducibility displayed relative standard deviations lower than 5%. Recovery tests performed in tap water, melon, and shrimp yielded mean values of 94 ± 6%, 97 ± 10% and 93 ± 10%, respectively. Moreover, several inorganic and organic compounds did not significantly interfere (0.6 to 4.5%) on the IMI signal, proving the selectivity and applicability of the developed sensor for IMI detection in complex samples.

摘要

一种简单而稳健的传感器(fMWCNT-Nafion®0.5%/GCE),用于测定广泛使用的新烟碱类农药吡虫啉(IMI),是使用玻碳电极(GCE)修饰功能化多壁碳纳米管(fMWCNT)和 Nafion®制备的。获得的数据表明,IMI 的还原是一个不可逆过程,这是由于硝基还原为羟胺衍生物,涉及两个质子和四个电子,以及一个电荷转移系数为 0.141。优化的方波伏安条件为:pH 6.0 的 McIlvaine 缓冲液、fMWCNT 悬浮液中 0.5%的 Nafion®、-0.6 V 和 180 s 作为累积电位和时间。在 2.00×10-7 至 1.77×10-6 mol L-1 IMI 的范围内呈现线性关系,检测限和定量限的值分别等于 3.74×10-8 mol L-1 和 1.25×10-7 mol L-1。重复性和重现性的相对标准偏差低于 5%。在自来水中、甜瓜和虾中进行的回收率测试,平均回收率分别为 94±6%、97±10%和 93±10%。此外,几种无机和有机化合物对 IMI 信号的干扰不明显(0.6 至 4.5%),证明了所开发传感器对复杂样品中 IMI 检测的选择性和适用性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验