Electrocautery-enhanced Lumen-apposing Metal Stents in the Management of Symptomatic Pancreatic Fluid Collections: Results From the Multicenter Prospective Pivotal Trial.

作者信息

Nieto Jose, Mekaroonkamol Parit, Shah Raj, Khashab Mouen A, Loren David E, Waxman Irving, Edmundowicz Steven A, Willingham Field F

机构信息

Borland-Groover Clinic, Jacksonville, FL.

Emory University School of Medicine, Atlanta, GA.

出版信息

J Clin Gastroenterol. 2023 Feb 1;57(2):218-226. doi: 10.1097/MCG.0000000000001545.

Abstract

BACKGROUND AND AIMS

Endoscopic decompression is considered a first-line treatment for symptomatic pancreatic fluid collections (PFCs). A lumen-apposing metal stent (LAMS) with an electrocautery-enhanced delivery system [electrocautery-enhanced lumen-apposing metal stent (ELAMS)] may facilitate this procedure. This study evaluated the safety and efficacy of ELAMS in the management of symptomatic PFCs.

PATIENTS AND METHODS

A multicenter, nonblinded, prospective, Food and Drug Administration (FDA)-approved, investigational device exemption clinical trial was conducted. Enrollment criteria included symptomatic PFCs ≥6 cm with ≥70% fluid fraction. Subjects were followed prospectively for safety, efficacy, and resolution of the collections. Primary endpoint success was defined as ≥50% reduction in PFC size. Clinical outcomes were compared with our previously published series of LAMS without the cautery-enhanced delivery system.

RESULTS

The target enrollment of 30 patients was achieved in 7 US tertiary care centers. All patients underwent successful placement of the ELAMS. The mean procedure duration, stent placement time, and fluoroscopy exposures were 28.1±12.5, 5.8±2.6, and 1.8±1.6 minutes, respectively. Eight patients had no fluoroscopy. The primary endpoint was achieved in 83.3% of patients. Two adverse events were attributed to the ELAMS: 1 bleeding upon stent removal and 1 stent migration. Relative to the comparator noncautery LAMS multicenter trial (N=33, 8 tertiary centers), there was a significantly shorter procedure duration [36 min ( P <0.001)] with similar technical and clinical outcomes in the ELAMS cohort.

CONCLUSION

LAMS placed using an electrocautery delivery system significantly reduce procedure duration and were safe and effective in the management of symptomatic PFCs.