Suppr超能文献

使用裂隙灯显微镜进行深度测量。

Depth measurement with the slit-lamp microscope.

作者信息

Perkins E S

机构信息

Department of Ophthalmology, University of Iowa Hospital, Iowa City 52242.

出版信息

Br J Ophthalmol. 1988 May;72(5):344-7. doi: 10.1136/bjo.72.5.344.

Abstract

The sagittal distance of ocular structures can be obtained with a slit-lamp microscope providing the movement of the slit-lamp can be measured. A simple device consisting of a pointer attached by a spring clip to the axle of a Haag-Streit 900 slit-lamp is described. The pointer rides over a scale which slides with the slit-lamp. Comparisons of anterior chamber depth and lens thickness showed a high correlation between this optical method and ultrasound measurements.

摘要

如果能够测量裂隙灯的移动,那么利用裂隙灯显微镜就可以获得眼部结构的矢状距离。本文描述了一种简单的装置,它由一个通过弹簧夹连接到Haag-Streit 900裂隙灯轴上的指针组成。指针在与裂隙灯一起滑动的刻度上移动。前房深度和晶状体厚度的比较表明,这种光学方法与超声测量之间具有高度相关性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b980/1041451/894c7304ced1/brjopthal00609-0026-a.jpg

相似文献

1
Depth measurement with the slit-lamp microscope.
Br J Ophthalmol. 1988 May;72(5):344-7. doi: 10.1136/bjo.72.5.344.
2
Anterior chamber depth measurement using the split-lamp microscope.
Am J Ophthalmol. 1979 Aug;88(2):236-8. doi: 10.1016/0002-9394(79)90471-9.
4
Device for eliminating corneal light reflections during recording of lateral images with a slit lamp.
Graefes Arch Clin Exp Ophthalmol. 1986;224(3):281-3. doi: 10.1007/BF02143070.
5
A new method of estimating the depth of the anterior chamber.
Br J Ophthalmol. 1979 Apr;63(4):215-20. doi: 10.1136/bjo.63.4.215.
7
Stereoscopic three-dimensional (3D) slit-lamp photography using a compact 3D digital camera.
Indian J Ophthalmol. 2021 May;69(5):1303-1305. doi: 10.4103/ijo.IJO_2037_20.
9
[Photographic documentation with the Haag-Streit slit lamp (author's transl)].
Klin Monbl Augenheilkd. 1980;177(2):245-8. doi: 10.1055/s-2008-1057642.
10
Slit-lamp studies of the rhesus monkey eye. I. Survey of the anterior segment.
Exp Eye Res. 1987 Feb;44(2):307-18. doi: 10.1016/s0014-4835(87)80014-3.

引用本文的文献

1
Lens thickness in early cataract.
Br J Ophthalmol. 1988 May;72(5):348-53. doi: 10.1136/bjo.72.5.348.

本文引用的文献

1
An apparatus for the measurement of the depth of the anterior chamber, based on the principle of Lindstedt.
Acta Ophthalmol (Copenh). 1953;31(3):265-70. doi: 10.1111/j.1755-3768.1953.tb03293.x.
2
Photometric oculometry. I. An analysis of the optical principles in slit-lamp fluorophotometry.
Acta Ophthalmol (Copenh). 1984 Apr;62(2):274-89. doi: 10.1111/j.1755-3768.1984.tb08404.x.
3
Slit-image photography.
Trans Ophthalmol Soc U K (1962). 1970;89:397-408.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验