In this study, the quality evaluation of homemade pumpkin, pear, wild plum and cabbage vinegar produced by traditional methods was carried out using the ultraviolet (UV) spectroscopy, rheology technique and Fourier transform infrared (FTIR) spectroscopy method. The measurement of UV spectra, flow behaviours and infrared spectral fingerprints of all the vinegars were performed in the wavelength range of 190 nm to 600 nm, shear rate of 10 s to 10 s and wavenumber of 4200 c to 400 cm at room temperature, respectively. The quality of homemade vinegars was correlated with the UV spectra peaks, which took values with acetic acid and phenolic compound concentrations. It was determined that the absorption coefficient and optical energy gaps (E) which were caused by the release time, depends on the organic acids content. It was observed that the UV spectra and forbidden energy gaps of all the vinegars compatible with the Lambert-Beer-Bouguer and Tauc laws, respectively. The flow behaviour of homemade vinegars was consistent with the non-Newtonian flow, which is the signature behaviour of the dilatant (thickening) and pseudo-plastic (thinning) liquids. Moreover, it was determined that the spectral fingerprint peaks obtained from FTIR spectroscopy were caused by the mixture of acetic acid and water forming the structure of the vinegar. As a result of spectroscopy and rheological analyses, which yields compatible results with commercial tests, it is predicted that it can be safely used as health test.
本研究采用紫外(UV)光谱、流变学技术和傅里叶变换红外(FTIR)光谱法,对传统方法酿造的南瓜、梨、野梅和白菜醋的质量进行了评价。在室温下,分别在波长范围为 190nm 至 600nm、剪切速率为 10s 至 10s 和波数为 4200cm 至 400cm 下,对所有醋的 UV 光谱、流动行为和红外光谱指纹进行了测量。醋的质量与 UV 光谱峰相关,UV 光谱峰的值与乙酸和酚类化合物的浓度有关。结果表明,吸收系数和光学能隙(E)是由释放时间引起的,这取决于有机酸的含量。观察到所有醋的 UV 光谱和禁带能隙都符合朗伯-比尔-布格定律和陶克定律。自制醋的流动行为与非牛顿流动一致,这是膨胀(变稠)和假塑性(变稀)液体的特征行为。此外,还确定了从 FTIR 光谱获得的光谱指纹峰是由形成醋结构的乙酸和水的混合物引起的。由于光谱和流变学分析与商业测试结果一致,预计它可以安全地用作健康测试。