Electromyography and Pelvic Floor Muscles Laboratory, Department of Physical Medicine, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland.
Department of Human Motor Behavior, Institute of Sport Science, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland.
PLoS One. 2021 May 18;16(5):e0251265. doi: 10.1371/journal.pone.0251265. eCollection 2021.
The primary aim of the study was to assess intraday and interday reliability of surface electromyography (sEMG) reflex activity of the pelvic floor muscles during synchronous whole-body vibration (S-WBV) of two intensities (30Hz/2mm; 40Hz/4mm) using band-stop filter and high-pass filter signal processing. The secondary aim of the study was to assess intraday and interday (test-retest) reliability of sEMG obtained from maximal voluntary contraction (MVC) test. We evaluated the intraday reliability of sEMG recordings obtained during sessions 1 and 2 performed on the same day. The sessions consisting of maximal voluntary pelvic floor muscle contraction and synchronous vibration sets with 1-hour rest in-between sessions 1 and 2 in healthy nulliparous women. The next intraday reliability was evaluated between the results of sessions 3 and 4 performed on the same day but followed at an interval of 4 weeks. to include the entire menstrual cycle. The interday reliability was determined based on the results of sessions 1 and 3 using the intraclass correlation coefficient (ICC 3,3). The intraday ICCs for band-stop filtered mean and median sEMG frequency and mean normalized sEMGRMS amplitude of the 30Hz/2mm (ICC = 0.89-0.99) and 40Hz/4mm vibration (ICC = 0.95-0.99) indicated substantial reproducibility. The intraday reliability of high-pass filter at 100-450Hz for these parameters was also substantial (30Hz/2mm ICC of 0.92 to 0.98; 40Hz/4mm ICC of 0.88 to 0.98). The interday reliability (session 1 vs. session 3) of the mean normalized sEMGRMS amplitude for band-stop filtered means of 40 Hz/4mm and 30Hz/2mm vibration recordings was substantial (ICC = 0.82 and 0.93). However, ICCs of the mean and median frequency were indicative of fair reliability (ICC of 0.43 to 0.59). The interday reliability of mean normalized sEMGRMS amplitude for high-pass filter at 100-450Hz was substantial (30Hz/2mm ICC of 0.90; 40Hz/4mm ICC of 0.73) for the 30Hz/2mm S-WBV and moderate (ICC = 0.73) for the 40/4mm S-WBV. The ICCs for mean and median sEMG frequency ICCs indicated slight to fair reproducibility (ICC of 0.16 to 0.56). The intraday reliability of the strongest MVC contraction and average MVC turned out substantial (ICC = 0.91-0.98). The interday reliability coefficients of the strongest MVC contraction and average MVCs were 0.91 and 0.82, respectively. Concluded, the intraday reliability proved satisfactory for all variables; however, the interday comparison showed sufficient ICC levels only for the mean amplitude. We therefore recommend this parameter should be used when analyzing PFM sEMG recorded during vibration. ICCs of the mean and median frequency for both signal processing methods were indicative of insufficient reliability and did not reach the threshold for usefulness. Our study showed similar reliability of PFM sEMG during S-WBV in case of the two filtering methods used.
本研究的主要目的是评估在两种强度(30Hz/2mm;40Hz/4mm)的全身同步振动(S-WBV)下,使用带阻滤波器和高通滤波器信号处理,评估盆底肌表面肌电图(sEMG)反射活动的日内和日间可靠性。本研究的次要目的是评估在最大自主收缩(MVC)测试中获得的 sEMG 的日内和日间(测试-再测试)可靠性。我们评估了在同一天的第 1 次和第 2 次会议期间获得的 sEMG 记录的日内可靠性。这些会议包括最大自主盆底肌肉收缩和同步振动,在第 1 次和第 2 次会议之间有 1 小时的休息。下一个日内可靠性是在同一天的第 3 次和第 4 次会议之间评估的,但相隔 4 周,以包括整个月经周期。日间可靠性是基于第 1 次和第 3 次会议的结果使用组内相关系数(ICC 3,3)来确定的。30Hz/2mm(ICC=0.89-0.99)和 40Hz/4mm 振动(ICC=0.95-0.99)的带阻滤波平均和中位数 sEMG 频率和平均归一化 sEMGRMS 幅度的日内 ICC 表明具有良好的可重复性。这些参数的高通滤波器在 100-450Hz 的日内可靠性也很高(30Hz/2mm 的 ICC 为 0.92 到 0.98;40Hz/4mm 的 ICC 为 0.88 到 0.98)。对于带阻滤波均值的 40Hz/4mm 和 30Hz/2mm 振动记录的平均归一化 sEMGRMS 幅度的日间可靠性(第 1 次会议与第 3 次会议)也是很好的(ICC=0.82 和 0.93)。然而,频率的均值和中位数的 ICC 表明可靠性为中等(ICC 为 0.43 到 0.59)。对于高通滤波器在 100-450Hz 的平均归一化 sEMGRMS 幅度的日间可靠性是很好的(30Hz/2mm 的 ICC 为 0.90;40Hz/4mm 的 ICC 为 0.73),对于 30Hz/2mm 的 S-WBV 是中度(ICC=0.73)。对于 40/4mm 的 S-WBV,sEMG 频率的 ICCs 表明轻微到中等的可重复性(ICC 为 0.16 到 0.56)。最强 MVC 收缩和平均 MVC 的日内可靠性是很好的(ICC=0.91-0.98)。最强 MVC 收缩和平均 MVC 的日间可靠性系数分别为 0.91 和 0.82。结论是,所有变量的日内可靠性都令人满意;然而,日间比较仅显示出平均幅度的足够 ICC 水平。因此,我们建议在分析振动期间记录的 PFM sEMG 时应使用此参数。两种信号处理方法的频率的均值和中位数的 ICC 表明可靠性不足,未达到有用性的阈值。我们的研究表明,在使用两种滤波方法的情况下,S-WBV 期间 PFM sEMG 的可靠性相似。