Suppr超能文献

基于扫频源光学相干断层血管造影的新型自动算法测量脉络膜新生血管体积和面积的验证。

Validation of a Novel Automated Algorithm to Measure Drusen Volume and Area Using Swept Source Optical Coherence Tomography Angiography.

机构信息

Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA.

Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, China.

出版信息

Transl Vis Sci Technol. 2021 Apr 1;10(4):11. doi: 10.1167/tvst.10.4.11.

Abstract

PURPOSE

The purpose of this study was to validate a novel automated swept source optical coherence tomography angiography (SS-OCTA) algorithm to measure elevations of the retinal pigment epithelium (RPE) in eyes with nonexudative age-related macular degeneration (neAMD).

METHODS

Patients with drusen were enrolled in a prospective optical coherence tomography (OCT) study and underwent both spectral domain OCT (SD-OCT) and SS-OCTA imaging at the same visit using the 6 × 6 mm scan patterns. The RPE elevation measurements (square root area and cube root volume) from the SS-OCTA algorithm were compared with the automated validated SD-OCT algorithm on the instrument. Standard deviations of drusen measurements from four repeated scans of another separate set were also calculated to evaluate the reproducibility of the SS-OCTA algorithm.

RESULTS

A total of 53 eyes from 28 patients were scanned on both instruments. A very strong correlation was found between the measurements from the two algorithms (all r > 0.95), although the measurements of the drusen area and volume were all larger from the SS-OCTA instrument. The reproducibility of the new SS-OCTA algorithm was analyzed using a sample of 66 eyes from 43 patients. The intraclass correlation coefficient (ICC) was greater than 99% from different macular regions for both the square root area and cube root volume measurements.

CONCLUSIONS

A novel automated SS-OCTA algorithm for the quantitative assessment of drusen was validated against the SD-OCT algorithm and was shown to be highly reproducible.

TRANSLATIONAL RELEVANCE

This novel SS-OCTA algorithm provides a strategy to measure the area and volume of drusen to assess disease progression in neAMD.

摘要

目的

本研究旨在验证一种新型自动化扫频源光相干断层扫描血管造影(SS-OCTA)算法,以测量非渗出性年龄相关性黄斑变性(neAMD)患者的视网膜色素上皮(RPE)抬高。

方法

纳入有玻璃膜疣的患者进行前瞻性光相干断层扫描(OCT)研究,并在同一次就诊时使用 6×6mm 扫描模式同时进行谱域 OCT(SD-OCT)和 SS-OCTA 成像。将 SS-OCTA 算法的 RPE 抬高测量值(平方根面积和立方根体积)与仪器上的自动验证 SD-OCT 算法进行比较。还计算了另一组四个重复扫描的玻璃膜疣测量值的标准偏差,以评估 SS-OCTA 算法的可重复性。

结果

共对 28 名患者的 53 只眼进行了两种仪器的扫描。两种算法的测量值之间存在很强的相关性(所有 r>0.95),尽管 SS-OCTA 仪器的玻璃膜疣面积和体积测量值均较大。使用来自 43 名患者的 66 只眼的样本分析了新的 SS-OCTA 算法的可重复性。对于平方根面积和立方根体积测量值,不同黄斑区域的内类相关系数(ICC)均大于 99%。

结论

针对玻璃膜疣定量评估的新型自动化 SS-OCTA 算法已针对 SD-OCT 算法进行了验证,且显示出高度的可重复性。

翻译

杨阳

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/24e5/8054634/a9367f6fface/tvst-10-4-11-f001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。