Suppr超能文献

使用 FreeStyle Libre 的 1 型糖尿病患者中糖尿病酮症酸中毒的频率:一项回顾性图表审查。

Frequency of Diabetic Ketoacidosis in Patients with Type 1 Diabetes Using FreeStyle Libre: A Retrospective Chart Review.

机构信息

Department of Endocrinology and Diabetes, Diabetes Treatment Center, Prince Sultan Military Medical City, P.O. Box 7897, Riyadh, 11159, Saudi Arabia.

出版信息

Adv Ther. 2021 Jun;38(6):3314-3324. doi: 10.1007/s12325-021-01765-z. Epub 2021 May 19.

Abstract

INTRODUCTION

Diabetic ketoacidosis (DKA) is an acute complication associated with poorly managed or undiagnosed diabetes. DKA is associated with significant morbidity, mortality, and healthcare costs, but can be prevented with appropriate management of diabetes. The FreeStyle Libre is flash glucose monitoring device that measures glucose levels in the interstitial subcutaneous tissue and has been shown to reduce HbA1c, time in hypoglycemia and hyperglycemia, as well as improve health-related quality of life.

METHODS

A retrospective chart review of patients with type 1 diabetes mellitus (T1DM) and recurrent DKA and who initiated FreeStyle Libre (Abbott Diabetes Care, Alameda, CA, USA) was conducted. DKA frequency and severity, glycated hemoglobin (HbA1c), and frequency of blood glucose monitoring were compared between the 2-year period before FreeStyle Libre initiation and the 2-year period after FreeStyle Libre initiation.

RESULTS

A total of 47 patients with T1DM with recurrent DKA were included. FreeStyle Libre was associated with a reduction in the frequency of DKA events, with a mean of 0.2 (standard deviation [SD] 0.4) events per person during the 2 years after FreeStyle Libre initiation versus 2.9 (SD 0.9) during the 2 years before FreeStyle Libre initiation. Severity of DKA events was also reduced, with fewer severe (before mean 0.3 [SD 0.5] versus after 0.0 [SD 0.0]; p < 0.001) DKA events. A reduction in HbA1c (mean 7.4% [SD 0.5] after versus 9.9% [SD 1.2] before [p < 0.001]) and an increase in frequency of blood glucose testing (mean 8.1 scans/day [SD 1.7] after versus 2.2 finger-pricks/day [SD 0.7] at before [p < 0.001]) were also observed.

CONCLUSION

FreeStyle Libre is associated with a reduction in the frequency and severity of DKA events, reduction in HbA1c, and increase in frequency of blood glucose testing in patients with T1DM and recurrent DKA. The use of such a glucose monitoring tool can help to reduce the burden of morbidity, mortality, and healthcare costs associated with complications of diabetes.

摘要

简介

糖尿病酮症酸中毒(DKA)是一种与未得到良好控制或未被诊断的糖尿病相关的急性并发症。DKA 与显著的发病率、死亡率和医疗保健成本相关,但通过适当的糖尿病管理是可以预防的。FreeStyle Libre 是一种连续血糖监测设备,可测量间质皮下组织中的葡萄糖水平,已被证明可以降低糖化血红蛋白(HbA1c)、低血糖和高血糖时间,并改善与健康相关的生活质量。

方法

对接受 FreeStyle Libre(雅培糖尿病护理,加利福尼亚州阿拉米达)治疗的 1 型糖尿病(T1DM)和复发性 DKA 患者进行了回顾性图表审查。在使用 FreeStyle Libre 前 2 年和后 2 年期间,比较了 DKA 发作频率和严重程度、糖化血红蛋白(HbA1c)以及血糖监测频率。

结果

共纳入 47 例复发性 DKA 的 T1DM 患者。FreeStyle Libre 与 DKA 事件频率降低相关,在使用 FreeStyle Libre 后的 2 年中,人均 DKA 事件发生率为 0.2(标准差 [SD] 0.4),而在使用 FreeStyle Libre 前的 2 年中为 2.9(SD 0.9)。DKA 事件的严重程度也有所降低,严重程度较低(使用前的平均 0.3 [SD 0.5]与使用后的 0.0 [SD 0.0];p<0.001)。HbA1c 降低(使用后平均 7.4%[SD 0.5],使用前平均 9.9%[SD 1.2];p<0.001)和血糖检测频率增加(使用后平均 8.1 次/天[SD 1.7],使用前平均 2.2 次/天[SD 0.7]指尖采血;p<0.001)也观察到。

结论

FreeStyle Libre 与 T1DM 和复发性 DKA 患者的 DKA 事件频率和严重程度降低、HbA1c 降低以及血糖检测频率增加相关。使用这种血糖监测工具可以帮助降低与糖尿病并发症相关的发病率、死亡率和医疗保健成本负担。