Suppr超能文献

使用近红外光谱技术测量休息和运动时的胫骨血液动力学和代谢。

Measuring tibial hemodynamics and metabolism at rest and after exercise using near-infrared spectroscopy.

机构信息

School of Physical Education and Sport, Central China Normal University, Wuhan, Hubei, China.

Department of Kinesiology, University of Georgia, Athens, GA, USA.

出版信息

Appl Physiol Nutr Metab. 2021 Nov;46(11):1354-1362. doi: 10.1139/apnm-2021-0135. Epub 2021 May 21.

Abstract

The bone vascular system is important, yet evaluation of bone hemodynamics is difficult and expensive. This study evaluated the utility and reliability of near-infrared spectroscopy (NIRS), a portable and relatively inexpensive device, in measuring tibial hemodynamics and metabolic rate. Eleven participants were tested twice using post-occlusive reactive hyperemia technique with the NIRS probes placed on the tibia and the medial gastrocnemius (MG) muscle. Measurements were made at rest and after 2 levels of plantarflexion exercise. The difference between oxygenated and deoxygenated hemoglobin signal could be reliably measured with small coefficients of variation (CV; range 5.7-9.8%) and high intraclass correlation coefficients (ICC; range 0.73-0.91). Deoxygenated hemoglobin rate of change, a potential marker for bone metabolism, also showed good reliability (CV range 7.5-9.8%, ICC range 0.90-0.93). The tibia was characterized with a much slower metabolic rate compared with MG ( < 0.001). While exercise significantly increased MG metabolic rate in a dose-dependent manner (all  < 0.05), no changes were observed for the tibia after exercise compared with rest (all  > 0.05). NIRS is a suitable tool for monitoring hemodynamics and metabolism in the tibia. However, the local muscle exercise protocol utilized in the current study did not influence bone hemodynamics or metabolic rate. NIRS can be used to monitor tibial hemodynamics and metabolism with good reliability. Short-duration local muscle exercise increased metabolic rate in muscle but not in bone. High level of loading and exercise volume may be needed to elicit measurable metabolic changes in bone.

摘要

骨骼的脉管系统很重要,但评估骨骼血液动力学较为困难且费用昂贵。本研究评估了近红外光谱(NIRS)作为一种便携式且相对廉价的设备,在测量胫骨血液动力学和代谢率方面的实用性和可靠性。11 名参与者使用闭塞后反应性充血技术进行了两次测试,将 NIRS 探头放置在胫骨和内侧腓肠肌(MG)上。在休息和 2 个跖屈运动水平下进行测量。氧合和去氧血红蛋白信号的差异可以通过小的变异系数(CV;范围 5.7-9.8%)和高组内相关系数(ICC;范围 0.73-0.91)可靠地测量。去氧血红蛋白变化率是骨骼代谢的潜在标志物,也表现出良好的可靠性(CV 范围 7.5-9.8%,ICC 范围 0.90-0.93)。与 MG 相比,胫骨的代谢率要慢得多(<0.001)。虽然运动以剂量依赖性方式显著增加 MG 的代谢率(均<0.05),但与休息相比,运动后胫骨没有观察到变化(均>0.05)。NIRS 是监测胫骨血液动力学和代谢的合适工具。然而,在当前研究中使用的局部肌肉运动方案并未影响骨骼血液动力学或代谢率。NIRS 可用于监测胫骨的血液动力学和代谢,具有良好的可靠性。短时间的局部肌肉运动增加了肌肉的代谢率,但没有增加骨骼的代谢率。可能需要高负荷和较大的运动量才能引起骨骼代谢的可测量变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验