Willett K M, Simmons C D, Bentley G
Institute of Orthopaedics, Royal National Orthopaedic Hospital, Stanmore, Middlesex, England.
J Bone Joint Surg Br. 1988 Aug;70(4):607-10. doi: 10.1302/0301-620X.70B4.3403607.
A prospective study of 120 consecutive total hip replacements showed that deep suction drains produced maximal drainage volumes in the first 24 hours. Their continued presence resulted in minimal further drainage, did not reduce the likelihood of haematoma formation and led in some cases to the spread of skin organisms into the wound.
一项对连续120例全髋关节置换术的前瞻性研究表明,深部吸引引流管在前24小时产生的引流量最大。引流管持续留置导致后续引流量极少,并未降低血肿形成的可能性,且在某些情况下会导致皮肤细菌扩散至伤口。