Assessment of the radionuclide angiographic left ventricular maximum time-varying elastance calculation in man.

作者信息

Starling M R, Gross M D, Walsh R A, Dell'Italia L J, Montgomery D G, Squicciarini S A, Blumhardt R

机构信息

University of Michigan, Dept. of Internal Medicine, Ann Arbor 48105.

出版信息

J Nucl Med. 1988 Aug;29(8):1368-81.

PMID:3404254
Abstract

This investigation was designed to determine whether left ventricular (LV) maximum time-varying elastance (Emax) calculations obtained using equilibrium radionuclide angiography (RNA) were comparable to those obtained using biplane contrast cineangiography (CINE), and whether simple, indirect P-V relations might provide reasonable, alternative estimates of Emax. Accordingly, we studied 19 patients with simultaneous high-fidelity micromanometer LV and fluid brachial artery (Ba) pressure recordings, CINE, and RNA under control conditions and during methoxamine and nitroprusside infusions. Emax was defined for CINE and RNA as the maximum slope of the linear relation of isochronal, instantaneous P-V data points obtained from each of the three loading conditions. The indirect P-V relations were similarly obtained from Ba peak (P) pressure versus minimum RNA LV volume (BaP/minV) and Ba dicrotic notch (di) pressure versus minimum RNA LV volume (Badi/minV) data points. The mean heart rates and LV (+)dP/dtmax values were minimally altered during the three loading conditions. The isochronal Emax values ranged from 1.40 to 6.73 mmHg/ml (mean 4.13 +/- 1.99 s.d. mmHg/ml) for CINE and from 1.48 to 7.25 (mean 4.35 +/- 1.81 mmHg/ml) for RNA (p = N.S.). Similarly, the unstressed volumes ranged from -10 to 80 ml (mean 30 +/- 23 ml) for CINE and from -8 to 77 ml (29 +/- 21 ml) for RNA (p = N.S.). The individual, isochronal Emax values by RNA correlated with those by CINE (r = 0.86). In 14 of the 19 patients, the BaP/minV and Badi/minV relations correlated with the isochronal Emax values calculated by RNA (r = 0.83 and 0.82, respectively), and these relations also correlated with the Emax values calculated by CINE (r = 0.82 and 0.78, respectively). The slope and V0 values for the BaP/minV and Badi/minV relations underestimated those for Emax by RNA and CINE (p less than 0.01 and p less than 0.05, respectively, for both). Thus, the isochronal Emax values calculated using RNA are comparable to those obtained using CINE in man. Moreover, indirect P-V relations underestimate these Emax values, but they are linearly related with the isochronal Emax values calculated by RNA and CINE. Consequently, these indirect P-V relations may provide a more simple, alternative estimate of LV contractile function in man.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验