Abstract

Breast implant surgery for cosmetic purposes is the most popular plastic surgery and it has been performed for over 100 years. Rupture of silicone gel-filled breast implants usually is asymptomatic and is one of the more dangerous complications due to free silicone migration. The aim of our study was to evaluate the diagnostic value of ultrasound (US) in the evaluation of the integrity of silicone breast implants and identify the main sign of intact and ruptured breast implants. In this retrospective study, the medical documentation of women who underwent breast implant surgery and US checkups at Tautrimas Aštrauskas Clinic in Kaunas, Lithuania, during 2015-2020 was analyzed. The patients were divided into two groups: patients with intact and ruptured breast implants. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) as well as the signs of implant integrity of US examination were evaluated. In this study, 76 women with bilateral breast implants ( = 152) were reviewed. On a US examination, ruptured implants were found in 41.1% ( = 61) of the cases; of them, 78.7% ( = 48) of the cases had ≥2 US signs of a ruptured implant, and in all these cases, implant rupture was confirmed at surgery. Overall, one US sign of a ruptured implant was found in 21.3% ( = 13) of the cases. Of them, inhomogeneous content in all cases ( = 3) was found in the intact implant group, and an abnormal implant shell was documented more often in the ruptured implant group, not intact one ( = 9, 90% vs. = 1, 10%). US had a diagnostic accuracy of 94.7%, sensitivity of 98.3%, specificity of 89.2%, PPV of 93.4%, and NPV of 97.1% in the evaluation of implant integrity. Our results show that US is a very reliable alternative in evaluating breast implant integrity and could be the investigation of choice for implant rupture, while MRI could be advocated only in inconclusive cases. Uneven implant shell was found to be the most important US sign of breast implant rupture. Based on the findings, we recommend performing US examination after breast augmentation surgery with silicone gel-filled implants annually.

摘要

出于美容目的的乳房植入物手术是最受欢迎的整形手术,已经进行了 100 多年。硅凝胶填充乳房植入物破裂通常是无症状的,是更危险的并发症之一,因为游离硅迁移。我们研究的目的是评估超声(US)在评估硅酮乳房植入物完整性方面的诊断价值,并确定完整和破裂乳房植入物的主要征象。在这项回顾性研究中,分析了 2015 年至 2020 年在立陶宛考纳斯的陶特里马斯·阿斯特劳斯卡斯诊所接受乳房植入物手术和 US 检查的女性的医疗记录。患者分为两组:完整和破裂的乳房植入物患者。评估了 US 检查的准确性、敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)以及植入物完整性的征象。在这项研究中,回顾了 76 名双侧乳房植入物女性(=152)。在 US 检查中,发现 41.1%(=61)的病例存在破裂的植入物;其中,78.7%(=48)的病例有≥2 个 US 征象提示植入物破裂,在所有这些情况下,手术均证实植入物破裂。总的来说,发现 21.3%(=13)的病例有 1 个 US 征象提示植入物破裂。其中,在所有情况下均发现完整植入物组存在不均匀内容物(=3),在破裂植入物组而非完整植入物组中更常记录到异常植入物外壳(=9,90%比=1,10%)。US 在评估植入物完整性方面的诊断准确性为 94.7%,敏感性为 98.3%,特异性为 89.2%,PPV 为 93.4%,NPV 为 97.1%。我们的结果表明,US 是评估乳房植入物完整性的非常可靠的替代方法,并且可能是评估植入物破裂的首选方法,而 MRI 只能在不确定的情况下提倡。不均匀的植入物外壳被发现是乳房植入物破裂的最重要的 US 征象。基于这些发现,我们建议每年对硅胶填充乳房植入物隆乳术后进行 US 检查。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6d69/8147634/08d7eefdfd24/medicina-57-00440-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验