Chen Andy Wei-Ge, Chen Mu-Kuan
Department of Otorhinolaryngology, Head and Neck Surgery, Changhua Christian Hospital, Changhua 500, Taiwan.
J Clin Med. 2021 May 11;10(10):2051. doi: 10.3390/jcm10102051.
The plasma blade is an innovative device that was recently introduced for performing tonsillectomy. While one of the benefits of the plasma blade is limited thermal damage, the effects of plasma blades on postoperative hemorrhage have not been thoroughly investigated. Patients who underwent tonsillectomy in our institution between January 2013 and September 2018 were retrospectively enrolled in the study. A total of 1214 patients were enrolled in the study, with 759 participants who underwent monopolar tonsillectomy and 455 participants who underwent plasma blade tonsillectomy. In total, 14 bleeding events occurred in the monopolar group, and 10 events occurred in the plasma blade group. The odds ratio for postoperative bleeding in the plasma blade group was 1.20 (95% CI 0.52 to 2.72). After adjusting for potential confounders, the adjusted odds ratio was 1.34 (95% CI 0.58 to 3.07). In conclusion, there is no significant difference in post-tonsillectomy hemorrhage rates between the traditional monopolar technique and plasma blade technique. Plasma blade tonsillectomy can be considered as safe as traditional monopolar tonsillectomy.
等离子刀是一种最近被引入用于扁桃体切除术的创新设备。虽然等离子刀的一个优点是热损伤有限,但等离子刀对术后出血的影响尚未得到充分研究。回顾性纳入了2013年1月至2018年9月期间在我们机构接受扁桃体切除术的患者。共有1214名患者纳入研究,其中759名接受单极扁桃体切除术,455名接受等离子刀扁桃体切除术。单极组共发生14例出血事件,等离子刀组发生10例。等离子刀组术后出血的比值比为1.20(95%可信区间0.52至2.72)。在对潜在混杂因素进行调整后,调整后的比值比为1.34(95%可信区间0.58至3.07)。总之,传统单极技术和等离子刀技术在扁桃体切除术后出血率方面没有显著差异。等离子刀扁桃体切除术可被认为与传统单极扁桃体切除术一样安全。