Suppr超能文献

横形肌皮骨(TMG)游离皮瓣用于自体乳房重建的安全性和供区并发症:系统评价和荟萃分析。

Safety and donor site morbidity of the transverse musculocutaneous gracilis (TMG) flap in autologous breast reconstruction-A systematic review and meta-analysis.

机构信息

Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Trauma Center Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, Ludwigshafen, Germany.

Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany.

出版信息

J Surg Oncol. 2021 Sep;124(4):492-509. doi: 10.1002/jso.26559. Epub 2021 Jun 6.

Abstract

BACKGROUND AND OBJECTIVES

The transverse musculocutaneous gracilis (TMG) flap has gained popularity for breast reconstruction. However, the literature regarding its donor site morbidity is heterogeneous. This systematic review sought to clarify the evidence on donor site morbidity.

METHODS

A systematic literature search was conducted. We included all articles reporting on donor-site morbidity of the TMG flap for breast reconstruction. The results were analyzed in R and its extension meta. A generalized linear mixed model was used to combine proportions and their 95% confidence intervals (CIs) in a random-effects meta-analysis.

RESULTS

Nineteen articles provided an overall sample of 843 TMG flaps. The total flap loss was low at 2% (95% CI, 1%-3%). All patients were normal weight (pooled body mass index 22.75, 95% CI, 21.88-23.63). The incidence of wound dehiscence (8%, 95% CI, 4%-16%), seroma (4%, 95% CI, 2%-7%), hematoma (2%, 95% CI, 1%-4%) and infection (0%-5%) on the TMG donor site was low. Functional impairments included sensory disturbance (0%-74%), motoric deficits (0%-50%), and changes in the genital region (0%-24%), all of which were modest.

CONCLUSIONS

This review confirms the safety and low donor site morbidity of the TMG flap in normal-weight patients, which is comparable to that of other popular free flaps in breast reconstruction.

摘要

背景与目的

横形肌皮骨(TMG)皮瓣在乳房重建中越来越受欢迎。然而,关于其供区并发症的文献存在异质性。本系统评价旨在阐明供区并发症的证据。

方法

进行了系统的文献检索。我们纳入了所有报道 TMG 皮瓣用于乳房重建的供区并发症的文章。结果在 R 及其扩展 meta 中进行分析。使用广义线性混合模型在随机效应荟萃分析中合并比例及其 95%置信区间(CI)。

结果

19 篇文章提供了 843 个 TMG 皮瓣的总体样本。总皮瓣失活率较低,为 2%(95%CI,1%-3%)。所有患者均为正常体重(合并身体质量指数 22.75,95%CI,21.88-23.63)。TMG 供区伤口裂开(8%,95%CI,4%-16%)、血清肿(4%,95%CI,2%-7%)、血肿(2%,95%CI,1%-4%)和感染(0%-5%)的发生率较低。功能障碍包括感觉障碍(0%-74%)、运动障碍(0%-50%)和生殖器区域改变(0%-24%),均为轻度。

结论

本综述证实了 TMG 皮瓣在正常体重患者中的安全性和低供区并发症发生率,与乳房重建中其他流行的游离皮瓣相当。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验