Suppr超能文献

Transmitral pressure-flow velocity relation. Importance of regional pressure gradients in the left ventricle during diastole.

作者信息

Courtois M, Kovács S J, Ludbrook P A

机构信息

Washington University School of Medicine, Cardiovascular Division, St. Louis, MO 63110.

出版信息

Circulation. 1988 Sep;78(3):661-71. doi: 10.1161/01.cir.78.3.661.

Abstract

Effects of regional diastolic pressure differences within the left ventricle on the measured transmitral pressure-flow relation were determined by simultaneous micromanometric left atrial (LAP) and left ventricular pressure (LVP) measurements, and Doppler echocardiograms in 11 anesthetized, closed-chest dogs. Intraventricular pressure recordings at sites that were 2, 4, and 6 cm from the apex were obtained. Profound differences between these sites were noted in the transmitral pressure relation during early (preatrial) diastolic filling. In measurements from apex to base, minimum LVP increased (1.6 +/- 0.7 to 3.1 +/- 0.8 mm Hg, mean +/- SD); the time interval between the first crossover of transmitral pressures and minimum LVP increased (31 +/- 3 to 50 +/- 17 msec); the slope of the rapid-filling LVP wave decreased (74 +/- 13 to 26 +/- 5 mm Hg/sec); the maximum forward (i.e., LAP greater than LVP) transmitral pressure gradient decreased (3.6 +/- 1.3 to 2.1 +/- 0.7 mm Hg); the time interval between the first and second points of transmitral pressure crossover increased (71 +/- 9 to 96 +/- 13 msec); and the area of reversed (i.e., LVP greater than LAP) gradient between the second and third points of transmitral pressure crossover decreased (101 +/- 41 to 40 +/- 33 mm Hg.msec). During atrial contraction, significant regional ventricular apex-to-base gradients were also noted. The slope of the LV A wave decreased (26 +/- 10 to 16 +/- 4 mm Hg/sec); LV end-diastolic pressure decreased (8.1 +/- 2.0 to 7.4 +/- 2.0 mm Hg), and the upstroke of the LV A wave near the base was recorded earlier than near the apex. All differences were significant at the 0.05 level. Simultaneous transmitral Doppler velocity profiles and transmitral pressures were measured at the 4-cm intraventricular site. The average interval between the first and second points of pressure crossover and between the onset of early rapid filling and maximum E-wave velocity were statistically similar (81 +/- 13 vs. 85 +/- 12 msec; NS); and the average area of the forward transmitral pressure gradient associated with acceleration of early flow was significantly greater than the area of reversed gradient associated with deceleration of early flow (133 +/- 36 vs. 80 +/- 46 msec.mm Hg; p less than 0.025).(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验