Ultrasound Med Biol. 2021 Sep;47(9):2702-2712. doi: 10.1016/j.ultrasmedbio.2021.04.028. Epub 2021 Jun 8.
This investigation assessed the processer reliability of estimating muscle volume and echo-intensity of the rectus femoris, tibialis anterior and semitendinosus. The muscles of 10 typically developing children (8.15 [1.40] y) and 15 children with spastic cerebral palsy (7.67 [3.80] y; Gross Motor Function Classification System I = 5, II = 5, III = 5) were scanned with 3-D freehand ultrasonography. For the intra-processer analysis, the intra-class correlations coefficients (ICCs) for muscle volume ranged from 0.943-0.997, with relative standard errors of measurement (SEM%) ranging from 1.24%-8.97%. For the inter-processer analysis, these values were 0.853 to 0.988 and 3.47% to 14.02%, respectively. Echo-intensity had ICCs >0.947 and relative SEMs <4% for both analyses. Muscle volume and echo-intensity can be reliably extracted for the rectus femoris, semitendinosus and tibialis anterior in typically developing children and children with cerebral palsy. The need for a single processer to analyze all data is dependent on the size of the expected changes or differences.
本研究评估了评估股直肌、胫骨前肌和半腱肌肌肉体积和回声强度的处理器可靠性。10 名典型发育儿童(8.15 [1.40] 岁)和 15 名痉挛性脑瘫儿童(7.67 [3.80] 岁;粗大运动功能分类系统 I = 5,II = 5,III = 5)的肌肉使用 3-D 自由手超声进行扫描。对于处理器内分析,肌肉体积的组内相关系数(ICC)范围为 0.943-0.997,测量相对标准误差(SEM%)范围为 1.24%-8.97%。对于处理器间分析,这些值分别为 0.853 至 0.988 和 3.47%至 14.02%。对于两种分析,回声强度的 ICC 均>0.947,相对 SEM 均<4%。股直肌、半腱肌和胫骨前肌的肌肉体积和回声强度可在典型发育儿童和脑瘫儿童中可靠提取。需要单个处理器来分析所有数据取决于预期变化或差异的大小。