Suppr超能文献

经颅直流电刺激(tDCS)对健康受试者社会认知表现的影响:一项随机假刺激对照交叉先导研究。

Effects of anodal multichannel transcranial direct current stimulation (tDCS) on social-cognitive performance in healthy subjects: A randomized sham-controlled crossover pilot study.

机构信息

Coimbra Institute for Biomedical Imaging and Translational Research (CIBIT), University of Coimbra, Coimbra, Portugal; Institute for Nuclear Sciences Applied to Health (ICNAS), University of Coimbra, Coimbra, Portugal; Faculty of Medicine, University of Coimbra, Coimbra, Portugal.

Coimbra Institute for Biomedical Imaging and Translational Research (CIBIT), University of Coimbra, Coimbra, Portugal; Institute for Nuclear Sciences Applied to Health (ICNAS), University of Coimbra, Coimbra, Portugal.

出版信息

Prog Brain Res. 2021;264:259-286. doi: 10.1016/bs.pbr.2021.04.004. Epub 2021 May 31.

Abstract

Recent studies suggest that temporoparietal junction (TPJ) modulation can influence attention and social cognition performance. Nevertheless, no studies have used multichannel transcranial direct current stimulation (tDCS) over bilateral TPJ to estimate the effects on these neuropsychological functions. The project STIPED is using optimized multichannel stimulation as an innovative treatment approach for chronic pediatric neurodevelopmental disorders, namely in children/adolescents with Autism Spectrum Disorder (ASD). In this pilot study, we aim to explore whether anodal multichannel tDCS coupled with a Joint Attention Task (JAT) influences social-cognitive task performance relative to sham stimulation, both in an Emotion Recognition Task (ERT) and in a Mooney Faces Detection Task (MFDT), as well as to evaluate this technique's safety and tolerability. Twenty healthy adults were enrolled in a randomized, single-blinded, sham-controlled, crossover study. During two sessions, participants completed the ERT and the MFDT before and after 20min of sham or anodal tDCS over bilateral TPJ. No significant differences on performance accuracy and reaction time were found between stimulation conditions for all tasks, including the JAT. A significant main time effect for overall accuracy and reaction time was found for the MFDT. Itching was the most common side effect and stimulation conditions detection was at chance level. Results suggest that multichannel tDCS over bilateral TPJ does not affect performance of low-level emotional recognition tasks in healthy adults. Although preliminary safety and tolerability are demonstrated, further studies over longer periods will be pursued to investigate the clinical efficacy in children/adolescents with ASD, where social cognition impairments are preponderant.

摘要

最近的研究表明,颞顶联合区(TPJ)的调节可以影响注意力和社会认知表现。然而,目前还没有研究使用双侧 TPJ 的多通道经颅直流电刺激(tDCS)来估计对这些神经心理功能的影响。STIPED 项目正在使用优化的多通道刺激作为一种创新的治疗方法,用于治疗慢性儿科神经发育障碍,即自闭症谱系障碍(ASD)儿童/青少年。在这项初步研究中,我们旨在探索经颅直流电刺激联合联合注意力任务(JAT)是否会影响社会认知任务的表现,相对于假刺激,在情绪识别任务(ERT)和穆尼面部检测任务(MFDT)中,以及评估该技术的安全性和耐受性。20 名健康成年人被纳入一项随机、单盲、假对照、交叉研究。在两次会议中,参与者在接受双侧 TPJ 的假刺激或阳极 tDCS 20 分钟前后完成了 ERT 和 MFDT。在所有任务中,包括 JAT,刺激条件之间的性能准确性和反应时间均无显著差异。MFDT 的整体准确性和反应时间存在显著的主要时间效应。瘙痒是最常见的副作用,刺激条件的检测处于随机水平。结果表明,双侧 TPJ 的多通道 tDCS 不会影响健康成年人的低水平情绪识别任务的表现。尽管初步证明了安全性和耐受性,但将进行进一步的长期研究,以调查 ASD 儿童/青少年的临床疗效,因为他们存在社交认知障碍。