一种新的缝线技术治疗脱位的人工晶状体的结果:襻上锁定环。

Outcomes of a new suture technique for the treatment of dislocated intraocular lenses: locked loop on the haptic.

机构信息

Department of Ophthalmology, Batigoz Eye Health Center, Izmir, Turkey.

Department of Ophthalmology, Manisa City Hospital, Izmir, Turkey.

出版信息

Int Ophthalmol. 2021 Nov;41(11):3663-3673. doi: 10.1007/s10792-021-01927-6. Epub 2021 Jun 26.

Abstract

PURPOSE

To evaluate surgical and refractive outcomes of a new sutured scleral fixation technique in the management of subluxated intraocular lenses (IOLs).

METHODS

Nineteen eyes treated with the new scleral fixation technique were included. The mean corrected distance visual acuity (CDVA), postoperative refraction error, mean endothelial cell count (ECC), and complications were recorded. All patients were evaluated immediately postoperatively, at 1 and 7 days, and then at 1, 3, and 6 months.

RESULTS

The mean duration of follow-up of the patients was 10 months (range, 6-15 months). The mean CDVA was 0.41 ± 0.1 logMAR (logarithm of minimum angle of resolution) preoperatively and was 0.08 ± 0.07 logMAR postoperatively. The mean astigmatism was - 2.22 ± 1.86 D preoperative and was - 0.86 ± 0.58 D postoperative. The mean preoperative and postoperative ECC was 2455 ± 288 and 2352 ± 288, respectively. One patient (5.26%) experienced vitreous hemorrhage, and two (10.52%) experienced intraocular pressure elevation. IOL tilt and decentralization, conjunctival erosion, and cystoid macular edema were not observed in any eyes during follow-up.

CONCLUSION

This new IOL repositioning technique can be applied in a short surgical time and provides a stable IOL centration on long-term follow-up.

摘要

目的

评估一种新的巩膜缝线固定技术在治疗半脱位眼内透镜(IOL)中的手术和屈光效果。

方法

纳入 19 只接受新巩膜固定技术治疗的眼睛。记录平均矫正远视力(CDVA)、术后屈光误差、平均内皮细胞计数(ECC)和并发症。所有患者均在术后即刻、术后第 1 天和第 7 天以及术后第 1、3 和 6 个月进行评估。

结果

患者的平均随访时间为 10 个月(范围,6-15 个月)。平均 CDVA 术前为 0.41±0.1 logMAR(最小角分辨率对数),术后为 0.08±0.07 logMAR。平均术前散光为-2.22±1.86 D,术后为-0.86±0.58 D。平均术前和术后 ECC 分别为 2455±288 和 2352±288。1 例(5.26%)患者发生玻璃体积血,2 例(10.52%)患者发生眼压升高。在随访期间,没有观察到任何一只眼睛出现 IOL 倾斜和偏心、结膜侵蚀和囊样黄斑水肿。

结论

这种新的 IOL 重定位技术可以在短时间内完成手术,并在长期随访中提供稳定的 IOL 中心位置。