Suppr超能文献

基于烟酸反应异常的首发精神分裂症潜在客观标志物。

A potential objective marker in first-episode schizophrenia based on abnormal niacin response.

机构信息

Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Psychotic Disorders, Shanghai 200030, PR China.

Institute of Mental Health, Suzhou Guangji Hospital, The Affiliated Guangji Hospital of Soochow University, Soochow University, Suzhou 215137, Jiangsu, China.

出版信息

Schizophr Res. 2022 May;243:405-412. doi: 10.1016/j.schres.2021.06.028. Epub 2021 Jun 26.

Abstract

The lack of objective diagnostic markers has long been a challenge in the clinical management of schizophrenia (SZ). The current bivariate cut-offs method is an objective quantification of niacin skin flush abnormality (NFA) for identifying the SZ subgroup. However, the sensitivity of approximately 30% limits the application of NFA as a marker for detecting SZ. A laser Doppler flowmeter was employed to test the niacin skin-flushing response in 123 patients with first-episode psychosis including first-episode SZ (FES, n = 82) and psychotic bipolar disorders (PBP, n = 41), and non-psychiatric comparisons (NPC, n = 80). We modified the bivariate cut-offs using a combination of the niacin concentration corresponding to the half-maximal blood flow response (EC) and a new quantitative indicator called the overall trend area (OTA). The NFA used this study method predicted FES in the NPC group with 57% sensitivity, 89% specificity, and 73% accuracy compared to the 28% sensitivity, 91% specificity, and 59% accuracy of the existing method. This novel method could discern FES from the PBP group with an accuracy of 62%, compared with the 45% of the old method. In addition, we also discuss whether the bivariate cut-offs were occasional by adjusting the cut-offs threshold. The experimental results showed that the sensitivity and specificity were most stable when using the study method. The study indicates that NFA using modified bivariate cut-offs may be a potential objective marker in FES, and the niacin skin test could be feasible for early diagnosis and treatment of SZ.

摘要

缺乏客观的诊断标志物一直是精神分裂症(SZ)临床管理的挑战。目前的双变量截止值方法是对烟酸皮肤潮红异常(NFA)进行客观量化,以确定 SZ 亚组。然而,约 30%的敏感性限制了 NFA 作为检测 SZ 标志物的应用。本研究采用激光多普勒血流仪检测了 123 例首发精神病患者(包括首发精神分裂症患者 82 例和精神病性双相障碍患者 41 例)和非精神病对照组患者 80 例的烟酸皮肤潮红反应。我们使用烟酸浓度与血流反应半最大值对应的双变量截止值(EC)和一个新的定量指标——整体趋势面积(OTA)相结合来修改双变量截止值。与现有的 28%的敏感性、91%的特异性和 59%的准确性相比,该研究方法用于预测 NPC 组中的 FES 时,NFA 的敏感性为 57%、特异性为 89%、准确性为 73%。与旧方法的 45%相比,该新方法能够以 62%的准确性将 FES 与 PBP 组区分开来。此外,我们还通过调整截止值阈值来讨论双变量截止值是否为偶然情况。实验结果表明,使用研究方法时,敏感性和特异性最稳定。研究表明,使用修改后的双变量截止值的 NFA 可能是 FES 的潜在客观标志物,烟酸皮肤试验可能有助于 SZ 的早期诊断和治疗。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验