CTBT Beijing National Data Centre and Beijing Radionuclide Laboratory, Beijing, China.
CTBT Beijing National Data Centre and Beijing Radionuclide Laboratory, Beijing, China.
Appl Radiat Isot. 2021 Oct;176:109846. doi: 10.1016/j.apradiso.2021.109846. Epub 2021 Jun 26.
In order to improve the detection sensitivity of Kr, an anti-cosmic HPGe γ spectrometer was established and a specific Marinelli beaker was designed for Kr measurement. Comparing to the non-anticoincidence γ spectrum, the integral background counts rate range from 20 to 2400 keV was reduced by a factor of 5.17 using anticoincidence shielding. The minimum detectable activity of Kr was 10.5 Bq within 24 h measurement in standard mode and that of 3.99 Bq in anticoincidence mode. The activity concentration of atmospheric Kr was preliminarily measured to be an average of 1.30 Bq/m in Beijing and corresponding minimum detectable concentration was 0.2 Bq/m.