Degot Matthieu, Blache Yoann, Vigne Grégory, Franger Gabriel, Neyton Lionel, Rogowski Isabelle
Laboratoire Interuniversitaire de Biologie de la Motricité EA 7424, Université de Lyon, UFRSTAPS, 27-29 Boulevard du 11 Novembre 1918, 69622, Villeurbanne Cedex, France.
Athletic France, 4 rue Jean Sarrazin, 69008, Lyon, France.
BMC Sports Sci Med Rehabil. 2021 Jul 6;13(1):72. doi: 10.1186/s13102-021-00301-4.
The Unilateral Seated Shot-Put Test (USSPT) consists of pushing an overweight ball as far as possible to assess upper extremity power unilaterally and bilateral symmetry. Literature however reports various body positions and upper limb pushing patterns to perform USSPT, demanding to provide additional guideline to achieve overweight ball push. This study therefore aimed at assessing the reliability and agreement of USSPT outcome measures when pushing an overweight ball in a horizontal direction.
Twenty-seven healthy male athletes performed two sessions, one week apart, of three unilateral pushes per upper limb using a 3-kg medicine ball, for which the distances were measured. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimum detectable change at a 95 % confidence level (MDC) and coefficient of variation (CV) were assessed for the pushing distances based on one, two or three trials per side to produce two outcome measures: the pushing distance per limb and USSPT Limb Symmetry Index (LSI) when dividing pushing distance of the dominant side by that of the non-dominant side.
The most reliable pushing distance per limb was obtained when averaging three pushing distances, normalized by body mass with the exponent 0.35. The mean USSPT LSI was 1.09 ± 0.10 for the first session and 1.08 ± 0.10 for the second session, highlighting good reliability and agreement (ICC = 0.82; SEM = 0.045; MDC = 0.124; CV = 5.02 %).
When the overweight ball is pushed in a horizontal direction, averaging the distances of three trials for both the dominant and non-dominant limbs is advised to provide the most reliable USSPT distance per limb and USSPT LSI.
单侧坐姿推铅球测试(USSPT)包括尽可能远地推一个超重球,以单侧评估上肢力量和双侧对称性。然而,文献报道了进行USSPT的各种身体姿势和上肢推球模式,需要提供额外的指导来完成超重球的推球动作。因此,本研究旨在评估在水平方向推超重球时USSPT结果指标的可靠性和一致性。
27名健康男性运动员,间隔一周进行两个阶段的测试,每个上肢使用3公斤药球进行三次单侧推球,并测量推球距离。基于每侧一次、两次或三次试验的推球距离,评估组内相关系数(ICC)、测量标准误差(SEM)、95%置信水平下的最小可检测变化(MDC)和变异系数(CV),以得出两个结果指标:每侧肢体的推球距离,以及将优势侧推球距离除以非优势侧推球距离得到的USSPT肢体对称指数(LSI)。
通过将三个推球距离平均,并按体重指数0.35进行归一化处理,可得到每侧肢体最可靠的推球距离。第一阶段的平均USSPT LSI为1.09±0.10,第二阶段为1.08±0.10,显示出良好的可靠性和一致性(ICC = 0.82;SEM = 0.045;MDC = 0.124;CV = 5.02%)。
当在水平方向推超重球时,建议对优势侧和非优势侧肢体的三次试验距离进行平均,以获得最可靠的每侧肢体USSPT距离和USSPT LSI。