Department of Radiology, Cliniques Universitaires St-Luc, Université Catholique de Louvain, Brussels, Belgium; Department of Radiology, University of Health Sciences, Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey.
Department of Diagnostic and Interventional Radiology, University Hospital of Cologne, Germany.
Eur J Radiol. 2021 Sep;142:109832. doi: 10.1016/j.ejrad.2021.109832. Epub 2021 Jun 24.
OBJECTIVES: Intramammary mass lesions are reportedly present in up to 5.8% of all contrast enhanced CT-examinations of the female chest. We aimed to assess whether their biological relevance can be estimated using spectral CT-datasets. METHODS: In this bicentric retrospective study patients with breast masses visualized on spectral CT-examinations from 07/2017 to 06/2019 were included. Lesions were characterized as malignant or benign based on histology and/or a stable follow-up of >2 years. Conventional CT-images, iodine density-maps, virtual monoenergetic-images (40 keV, 100 keV) and Zeffective-maps were evaluated by two independent readers. Statistical analysis derived from the Regions of interest (ROIs) was done by calculating the Areas under the Receiver operating characteristic (ROC) curve (AUC) and Youden-indices. RESULTS: 106 breast masses (malignant/benign: 81/25, 76.4%/23.6%) were included. The mean AUCs of the variables "iodine content" (reader 1/2:0.97;0.98), "monoenergetic curve-slope" (0.97;0.96) and "Zeffective" (0.98;0.98) measured in the target lesions (TL) showed superior results compared to those derived from the variable "density" (0.92;0.93) (p < 0.001). The ratios "TL to aorta" calculated for the variables "iodine content", "monoenergetic curve-slope" and "Zeffective" showed superior results compared to normal breast tissue and muscle (p < 0.001). The optimal cutpoint for the "iodine content" in the TL was 0.7-0.9 mg/ml (sensitivity 96.6%, specificity 91.7%). The best diagnostic results were achieved by normalizing the iodine content in the TL to that in the aorta (optimal cutpoint 0.1, sensitivity 95.5%, 98.9%, specificity 91.7%). CONCLUSIONS: Our preliminary results suggest that spectral CT-datasets might allow to estimate the biological dignity of breast masses detected on clinically indicated chest-examinations.
目的:据报道,在所有女性胸部对比增强 CT 检查中,乳腺内肿块的检出率高达 5.8%。我们旨在评估其生物学相关性是否可以通过能谱 CT 数据集来评估。
方法:本研究为回顾性双中心研究,纳入了 2017 年 7 月至 2019 年 6 月期间在能谱 CT 检查中发现乳腺肿块的患者。根据组织学和/或 2 年以上的稳定随访,将病变分为恶性或良性。由两名独立的读者评估常规 CT 图像、碘密度图、虚拟单能量图像(40keV、100keV)和 Zeffective 图。通过计算受试者工作特征(ROC)曲线下面积(AUC)和 Youden 指数,对来自感兴趣区域(ROI)的统计分析进行了推导。
结果:共纳入 106 个乳腺肿块(恶性/良性:81/25,76.4%/23.6%)。病变(TL)中“碘含量”(读者 1/2:0.97;0.98)、“单能量曲线斜率”(0.97;0.96)和“Zeffective”(0.98;0.98)的平均 AUC 优于“密度”(0.92;0.93)(p<0.001)。“碘含量”、“单能量曲线斜率”和“Zeffective”的“TL 与主动脉比值”优于正常乳腺组织和肌肉(p<0.001)。TL 中碘含量的最佳截断值为 0.7-0.9mg/ml(敏感性 96.6%,特异性 91.7%)。通过将 TL 中的碘含量与主动脉中的碘含量进行归一化,获得了最佳的诊断结果(最佳截断值 0.1,敏感性 95.5%,98.9%,特异性 91.7%)。
结论:我们的初步结果表明,能谱 CT 数据集可能有助于评估临床指示性胸部检查中发现的乳腺肿块的生物学特征。
Radiology. 2019-1-15
Eur J Radiol. 2019-7-16
Quant Imaging Med Surg. 2024-10-1
Precis Radiat Oncol. 2023-12-1
Quant Imaging Med Surg. 2024-10-1
Quant Imaging Med Surg. 2022-12